Sheath Clean Air Barrier Static Eliminator
SJ-V series
Recommended Replaceable Products: Ultra High Speed Sensing Ionizer Hybrid Type - SJ-E series
Contact Us: 1-800-103-0090 Enquiry form
Bar Type Main Unit 1560 mm SJ-V156
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model | SJ-V156*1*2 | |||
Ion generation method | Corona discharge | |||
Structure | Shock-proof, resistance-coupled | |||
Voltage application method/applied voltage | Pulse AC method/±7,000 V | |||
Ion balance control method | I.C.C. method | |||
Ion balance | ±30 V*3 | |||
Operating distance | 50 to 2,000 mm | |||
Control input | NPN open collector or non-voltage contact signal | |||
Controloutput | NPN type photorelay: max. 100 mA (40 V or less) | |||
Major functions | Condition alarm output, ion level alarm output, alarm output | |||
Air purge connection port | M5 | |||
Air purge supplied pressure | 0.2 MPa or less | |||
Effective length | 1560 mm | |||
Total length | 1631 mm | |||
Effective length | 1560mm*4 | |||
Rating | Power voltage | 24 to 36 VDC ±10 % | ||
Current consumption | 250 mA (at 24 VDC)/150 mA (at 36 VDC) | |||
Environmental resistance | Pollution degree | 2 | ||
Overvoltage category | I | |||
Ambient temperature | 0 to +50 °C | |||
Relative humidity | 35 to 85 % RH (No condensation) | |||
Materials | Electrode probes | Tungsten | ||
Material | Ground electrode | Stainless steel | ||
Main unit | ABS plastic | |||
Weight | Bar | Approx 1,550 g | ||
*1 Silicon pin electrode types have (C) appended to the end of the model. (Separate specification, please inquire) |