Manual-Calibration Fibreoptic Sensor

FS-V/T/M series

This model has been discontinued.
Compliance with the certification standard is ensured as of the time of shipment from our company.

Fibre Amplifier, Cable Type, Main Unit, PNP FS-T1P

FS-T1P - Fibre Amplifier, Cable Type, Main Unit, PNP

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

  • CE Marking

Specifications

Model

FS-T1P

Type

Main unit

Output

PNP

Light source

Red LED

Sensitivity adjustment/Mode selection

Button

Response time

250 µs

Operation mode

LIGHT-ON/DARK-ON (switch-selectable)

Indicator lamp

Output indicator: Red LED, Stable operation indicator: Green LED Calibration indicator: Orange LED

Timer function

ON-delay: 40 ms/OFF-delay: 40 ms/Timer OFF (switch-selectable)

Input

Non-voltage input (contact, solid state)

Control output

PNP open-collector 100 mA max. (40 VDC max.), Residual voltage: 1 V max.

Stability output

PNP open-collector 50 mA max. (40 VDC max.), Residual voltage: 1 V max.*1

Protection circuit

Reversed polarity protection, Overcurrent protection, Surge absorber

Unit expansion

Up to 16 expansion units can be connected (a total of 17 units)*2

Mutual interference suppression

4

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Current consumption

35 mA or less

Environmental resistance

Ambient light

Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

Ambient temperature

-10 to +55 °C (No freezing)*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Polycarbonate

Accessories

Fittings

Weight

Approx. 75 g

*1 Only the FS-T1 and FS-M1 can provide stability outputs.
*2 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
3 to 10 Units: -10 to +50°C (14 to 122°F), 11 to 16 Units: -10 to +45°C (14 to 113°F)
*3 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When extended