Specs 2D/3D Laser Profiler LJ-X8000 series

Controller

Model

LJ-X8000

LJ-X8000E

Image

Head input

Up to 2 head units
Compatible with LJ-X8000 Series heads and LJ-V7000 Series heads *When using 2 units, heads A and B are the same model.

Sampling cycle (trigger interval)

[2D mode] Maximum speed of 1 kHz (1 ms) *1
[3D mode] When connecting the LJ-X8000 Series: maximum speed of 16 kHz (63 μs) *2
When connecting the LJ-V7000 Series: maximum speed of 64 kHz (16 μs) *3
(Luminance output types for model designations ending with B have a maximum speed of 8 kHz (125 μs)) *4

[2D mode] Maximum speed of 1 kHz (1 ms) *1
[3D mode] -

Number of registered inspection settings

Up to 1000 (depending on SD card capacity and setting contents) for each of SD cards 1 and 2. External switching is possible

Master profile / number of reference images

[2D mode] Maximum 200 per setting per head (depends on SD card capacity)
[3D mode] Maximum 400 per setting (depends on SD card capacity)

Maximum 200 per setting per head (depends on SD card capacity)

Memory card

• SD card slot × 2
• Supports OP-87133 (512 MB), CA-SD1G (1 GB), CA-SD4G (4 GB), CA-SD16G (16 GB)
*In the SD1 slot, CA-SD4G is equipped as standard for 8000, and CA-SD1G is equipped as standard for 8000E

Number of tools

[2D mode] 100/setting (of those, 20 are for misalignment correction)
[3D mode] Maximum of 100/setting

100/setting (of those, 20 are for misalignment correction)

Interface

Control input

20 points (input terminal block: 5 points, parallel I/O: 15 points)

Control output

28 points (output terminal block: 6 points, parallel I/O: 22 points)
• Photo MOSFET*5

RS-232C

• Value output and control I/O (exclusive use with PLC link using an RS-232C port)
• Supports baud rates up to 230,400 bps

PLC link

• Value output using Ethernet port or RS-232C port, and control I/O
(Exclusive use with EtherNet/IP™. When using an RS-232C port, exclusive use with RS-232C no-procedure communication)

Ethernet

• Value output and control I/O
• In addition to the above functions, can upload/download inspection settings, perform various simulations, send/receive various data including profile and image data, and be used with remote connection programmes via KEYENCE PC application software
• Supports FTP client and FTP server functions
• Supports VNC server functions (for non-PC clients, only displaying the monitor screen is supported)
• Supports BOOTP functions
• 1000BASE-T/100BASE-TX/10BASE-T
• Supports jumbo frames (when connected to any of CB-NEC20E/NEP20E/NPN20E)

USB

• Can output values (3D mode only), upload/download inspection settings, perform various simulations, send/receive various data including profile and image data, and be used with remote connection programmes via KEYENCE PC application software
• Dedicated USB 2.0

EtherNet/IP™

• Value I/O and control I/O using Ethernet port (exclusive use with PLC link)
• Supports cyclic communication (max. 1436 bytes) and message communication
• Maximum Connections: 32
• Conforms to Version.CT15 conformance test

PROFINET

• Value input and control input/output using Ethernet port (when this is in use, PLC-Link and EtherNet/IP™ cannot be used)
• Supports cyclic communication (max. 1408 bytes)
• Supports non-cyclic communication (record data)
• Conforms to Conformance Class A

EtherCAT®

• Can output numerical values and perform control I/O by connecting the optional EtherCAT® unit CB-NEC20E
(Cannot be used with PLC link, EtherNet/IP™, and PROFINET)
• Supports cyclic communication (process data object communication) (Input: Max. 536 bytes/Output: Max. 532 bytes)
• Supports acyclic communication (mailbox communication)
• Supports CoE
• Explicit Device Identification
• Complies with V2.2.10 and V2.2.1.0 conformance test

Mouse

Various menus can be controlled via the dedicated mouse (included with the controller)

SNTP

Automatic correction of date and time for this unit is possible by connecting to an SNTP server

USB HDD

By connecting an HDD (max. 2 TB) to the dedicated USB port (supports USB 3.0, bus-powered, rated output: 900 mA), profile, image and other data can be output

Monitor output

Analogue RGB output, XGA 1024 × 768 (24-bit colour, 60 Hz)

Encoder input

1 port: combination RS-422 line-driver output (with 5 V output: maximum 150 mA) open collector output (compatible with 5 V, 12 V, 24 V)

Response frequency

RS-422

Single phase / Z phase: 1.6 MHz, 2 phase / 1x: 1.6 MHz, 2 phase / 2x: 3.2 MHz, 2 phase / 4x: 6.4 MHz

Open collector (OC)

Single phase / Z phase: 100 kHz, 2 phase / 1x: 100 kHz, 2 phase / 2x: 200 kHz, 2 phase / 4x: 400 kHz

Laser ON input

Non-voltage input (Shorted with short pin when shipped from factory)

Cooling fan

Provided

Minimum display unit

[2D mode] 0.1 µm, 0.01°, 0.00001 mm2
[3D mode] 0.1 µm, 0.001°, 0.0001 mm2, 0.00001 mm3

0.1 µm, 0.01°, 0.00001 mm2

Language

Switchable between English, Japanese, Simplified Chinese, Traditional Chinese, Korean, German, French, Italian, Thai, Czech, Hungarian, and Polish

Ratings

Power voltage

24 V DC ±10%

Maximum current consumption

3.3 A

Environmental resistance

Ambient temperature

0 to +45°C (DIN rail mounting) / 0 to +40°C (base surface mounting)

Relative humidity

85% RH or less (no condensation)

Weight

Approx. 2500 g

*1 For LJ-X8080 and LJ-X8200 connection, when binning (Z) is ON, or when the measurement range (Z) is set to 1/2. LJ-X8900 when the measurement range (Z) is set to 1/2.
*2 When the measurement range is narrowed in accordance with the binning settings.
*3 When the measurement range is set to minimum, binning is ON, and parallel imaging is ON. All other settings are default values.
*4 When binning and parallel imaging are both ON. All other settings are default values.
*5 Positive common connection is supported for NPN input devices, and negative common connection for PNP input devices.

Back to top

Controller

Model

LJ-X8000A

Image

Head input

1 unit, compatible with LJ-X8000 Series heads and LJ-V7000 Series heads

Sampling cycle (trigger interval)

When connecting the LJ-X8000 Series: maximum speed of 16 kHz (63 μs) *1
When connecting the LJ-V7000 Series: maximum speed of 64 kHz (16 μs) *2
(Luminance output types for model designations ending with B have a maximum speed of 8 kHz (125 μs)) *3

Interface

Control input

Compatible with batch measurement start (MEASURE_START) and batch measurement stop (MEASURE_STOP)

Control output

Compatible with trigger ready (READY) and system error (ERROR), Photo MOSFET *4

Synchronised I/O

For multiple controller trigger synchronisation *5

Ethernet

Profile output, settings, control, 1000BASE-T/100BASE-TX*6

Encoder input

1 port: combination RS-422 line-driver output (with 5 V output: maximum 150 mA) open collector output (compatible with 5 V, 24 V)

Response frequency

RS-422

Single phase / Z phase: 1.6 MHz, 2 phase / 1x: 1.6 MHz, 2 phase / 2x: 3.2 MHz, 2 phase / 4x: 6.4 MHz

Open collector (OC)

Single phase / Z phase: 100 kHz, 2 phase / 1x: 100 kHz, 2 phase / 2x: 200 kHz, 2 phase / 4x: 400 kHz

Laser ON input

Non-voltage input (Shorted with short pin when shipped from factory)

Ratings

Power voltage

24 V DC ±10%

Maximum current consumption

1.3 A

Environmental resistance

Ambient temperature

0 to 45°C (DIN rail mounting) / 0 to 40°C (Horizontal)

Relative humidity

85% RH or less (no condensation)

Weight

Approx. 700 g

*1 When the measurement range is narrowed in accordance with the binning settings.
*2 When the measurement range is set to minimum, binning is ON, and parallel imaging is ON. All other settings are default values.
*3 When binning and parallel imaging are both ON. All other settings are default values.
*4 Positive common connection is supported for NPN input devices, and negative common connection for PNP input devices.
*5 Exclusively for synchronised I/O between controllers (LJ-X8000A).
*6 The PC application (LJ-H2X) includes communication libraries (DLL) and a sample programme. Types of communication libraries (DLL): Profile output, changing various settings, laser ON/OFF control, trigger input, etc.

Back to top

Sensor head

Model

LJ-X8020

LJ-X8060

LJ-X8080

LJ-X8200

LJ-X8300

LJ-X8400

LJ-X8900

Image

Reference distance

20 mm

64 mm

73 mm

245 mm

288 mm

380 mm

980 mm

Measurement range

Z-axis (height)

±2.2 mm
(F.S.=4.4 mm)

±7.3 mm
(F.S.=14.6 mm)

±20.5 mm
(F.S.=41 mm)

±34 mm
(F.S.=68 mm)

±53 mm
(F.S.=106 mm)

±60 mm (+95 to -220 mm*13)
(F.S.=315 mm)

±400 mm
(F.S.=800 mm)

X-axis (width)

NEAR side

7 mm

15 mm

30 mm

64 mm

134 mm

180 mm(163 mm*13)

300 mm

Reference distance

7.5 mm

16 mm

35 mm

72 mm

150 mm

210 mm

510 mm

FAR side

8 mm

39 mm

80 mm

160 mm

240 mm(320 mm*13)

720 mm

Light source

Blue semiconductor laser

Light source

Wavelength

405 nm (visible light)

Laser class

Class 2M laser product (IEC60825-1, FDA (CDRH) Part 1040.10*1)*2

Output

10 mW

Spot size

Approx. 16 mm × 32 µm
(reference distance)

Approx. 25 mm × 49 µm
(reference distance)

Approx. 44 mm × 72 µm
(reference distance)

Approx. 115 mm × 116 µm
(reference distance)

Approx. 215 mm × 108 µm
(reference distance)

Approx. 275 mm × 249 µm
(reference distance)

Approx. 622 mm × 566 µm
(reference distance)

Repeatability

Z-axis (height)

0.3 µm*3*4

0.4 µm*3*4

0.5 µm*3*4

1 µm*3*4

3 µm*3*4

5 µm*3*4

10 µm*3*4

X-axis (width)

0.3 µm*3*5

0.5 µm*3*5

1.0 µm*3*5

3 µm*3*5

5 µm*3*5

10 µm*3*5

25 µm*3*5

Linearity

Z-axis (height)

±0.05% of F.S. (±0.012%)*6

±0.04% of F.S. (±0.008%)*6

±0.03% of F.S. (±0.004%)*6

±0.04% of F.S. (±0.006%)*6

±0.033% of F.S. (±0.005%)*6

Reference distance: ±60 mm
±0.025% of F.S. (±0.003%)
Total range:
±0.035% of F.S. (±0.005%)*6

Near~reference: distance
±0.015% of F.S. (±0.004%)
Total range:
±0.05% of F.S. (±0.006%)*6

Profile data interval

X-axis (width)

2.5 µm (2 µm~)*7*8

5 µm (4 µm~)*7*8

12.5 µm (10 µm~)*7*8

25 µm (20 µm~)*7*8

50 µm (40 µm~)*7

75 µm (50 µm~)
100 µm (50 µm~)*13*7*8

225 µm (100 µm~)*7*8

Profile data count

3200 points

HDR (high dynamic range)

Single-shot HDR*9

Laser irradiation position confirmation function

Light source

Blue LED (405 nm)

Temperature characteristic

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529)*10

Ambient light

Incandescent lamp: 10,000 lux or less*11

Ambient temperature

0 to +45°C*12

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 57 Hz, double amplitude 1.5 mm; 3 hours each for X, Y, and Z axes

Shock resistance

15 G / 6 msec

Material

Aluminium

Weight

Approx. 1000 g

Approx. 1100 g

Approx. 1200 g

Approx. 1400 g

Approx. 1300 g

Approx. 1600 g

*1 Classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Values measured by averaging 4096 times at the reference distance.
*4 The measured target is a KEYENCE standard target. Value when the average height of the default setting area is measured with height and position tools. All other settings are default values.
*5 The measured target is a pin gauge. Value when the point of intersection for the pin gauge rounded surface and edge level is measured using height and position tools. All other settings are default values.
*6 The measured target is a KEYENCE standard target. Profile data when measured by smoothing 64 times and averaging 8 times. All other settings are default values. Values inside parentheses are representative examples of averages for all profile data.
*7 The profile data interval can be changed. If changed, the measurement range in the X direction will also change.
*8 Values inside parentheses cannot be used when connecting with LJ-X8000A.
*9 A characteristic that allows for stable, high-precision measurement with a single capture (exposure) at all levels of reflectance, from black (low) to glossy surfaces (high).
*10 The value when a head cable (CB-B*) or extension cable (CB-B*E) is connected. Does not include CB-B**L connection.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.
*13 When range is extended.

Back to top