AC Servo Systems
SV series
Specs AC Servo Systems SV series
Model |
SV-005P2 |
SV-010P2 |
SV-020P2 |
SV-040P2 |
SV-075P2 |
|||
Image |
|
|
|
|
|
|||
Power supply/current capacity and power loss |
Maximum applicable motor capacity Three-phase 200 VAC |
50 W |
100 W |
200 W |
400 W |
750 W |
||
Maximum applicable motor capacity Single-phase 200 VAC |
||||||||
Power capacity (VA) per amplifier Single-phase 100 VAC |
― |
|||||||
Power capacity (VA) per amplifier Three-phase 200 VAC |
200 VA |
300 VA |
600 VA |
1000 VA |
1600 VA |
|||
Power capacity (VA) per amplifier Single-phase 200 VAC |
700 VA |
1200 VA |
1900 VA |
|||||
Output current Continuous |
Single-phase 100 VAC |
― |
||||||
Three-phase 200 VAC |
0.66 Arms |
0.91 Arms |
1.6 Arms |
2.8 Arms |
5.5 Arms |
|||
Single-phase 200 VAC |
||||||||
Output current Maximum |
Three-phase 200 VAC |
2.1 Arms |
2.9 Arms |
5.8 Arms |
9.3 Arms |
16.9 Arms |
||
Single-phase 200 VAC |
||||||||
Main circuit power loss Three-phase 200 VAC |
5.1 W |
7.3 W |
13.5 W |
24 W |
43.8 W |
|||
Main circuit power loss Single-phase 200 VAC |
5.2 W |
7.4 W |
13.7 W |
24.9 W |
52.7 W |
|||
Built-in regenerative resistor power loss Single-phase 100 VAC |
― |
|||||||
Built-in regenerative resistor power loss Three-phase 200 VAC |
― |
8 W |
||||||
Built-in regenerative resistor power loss Single-phase 200 VAC |
||||||||
Control circuit power loss Single-phase 100 VAC |
17 W |
― |
||||||
Control circuit power loss Three-phase 200 VAC |
17 W |
|||||||
Control circuit power loss Single-phase 200 VAC |
||||||||
Total power loss Three-phase 200 VAC |
22.1 W |
24.3 W |
30.5 W |
41 W |
68.8 W |
|||
Total power loss Single-phase 200 VAC |
22.2 W |
24.4 W |
30.7 W |
41.9 W |
77.7 W |
|||
Input rated current |
Main circuit Three-phase 200 VAC |
1 Arms |
2 Arms |
3 Arms |
6 Arms |
|||
Main circuit Single-phase 200 VAC |
2 Arms |
3 Arms |
5 Arms |
9 Arms |
||||
Control circuit Three-phase 200 VAC |
0.2 Arms |
|||||||
Control circuit Single-phase 200 VAC |
||||||||
Rush current |
Main circuit Single-phase 100 VAC |
―*1 |
||||||
Main circuit Three-phase 200 VAC |
33 A*1 |
|||||||
Main circuit Single-phase 200 VAC |
||||||||
Control circuit Single-phase 100 VAC |
―*1 |
|||||||
Control circuit Three-phase 200 VAC |
70 A*1 |
33 A*1 |
||||||
Control circuit Single-phase 200 VAC |
||||||||
General specifications |
Type |
For 200 V |
||||||
Capacity |
50W |
100W |
200W |
400W |
750W |
|||
Input power supply |
Voltage/frequency |
Main circuit |
3-phase (or single-phase) 200 to 230 VAC, 50/60 Hz, 270 to 320 VDC |
|||||
Control circuit |
Single-phase 200 to 230 VAC, 50/60 Hz |
|||||||
Main circuit/control circuit |
Allowable voltage fluctuation |
170 to 253 VAC |
||||||
Allowable frequency fluctuation |
±5% or less |
|||||||
Allowable instantaneous outage time |
Main circuit |
Full-stop (100% down): 0.5 cycles, half-stop (50% down): 1 cycle |
||||||
Control circuit |
Approx 100ms |
|||||||
Overvoltage category |
III |
|||||||
Control method |
3-phase full-wave rectification, IGBT, PWM control, sine wave current drive method |
|||||||
Feedback |
20-bit serial encoder (incremental, absolute) communication |
|||||||
Operating environment |
Operating ambient temperature |
0 to +55°C (no freezing) |
||||||
Ambient storage temperature |
-20 to +70°C (no freezing) |
|||||||
Ambient operating/storage humidity |
90%RH or less (no condensation) |
|||||||
Vibration resistance |
4.9 m/s2 (conforms to JIS C 60068-2-6) |
|||||||
Shock resistance |
19.6 m/s2 (conforms to JIS C 60068-2-27) |
|||||||
Operating atmosphere (enclosure rating/pollution degree) |
Pollution degree: 2 (within a control panel that has a rating of IP54 or higher), however, · No corrosive or flammable gas present · A location that is not subject to water, oil, or drugs · No dust present |
|||||||
Altitude |
1,000 m or less above sea level |
|||||||
Approved standards |
UL/CSA standards |
UL508C, CSA C22.2 number 14 |
||||||
CE marking |
Low-voltage directive |
EN50178 |
||||||
EMI |
EN55011 Class A, EN61800-3 |
|||||||
EMS |
EN61800-3, EN61000-6-2 |
|||||||
North American EMI standards |
FCC Part 15 B, ICES-003, Class A |
|||||||
Structure |
Type |
Base mounting attachment |
||||||
Protection |
Open, forced |
|||||||
Lowest insulation resistance value |
1 MΩ or more, tested with a 500 VDC megger |
|||||||
Insulation withstand voltage |
1,500 VAC or more (between the primary side and the earth terminal), 1,800 VAC or more (between the primary side and the secondary side) |
|||||||
Weight |
Approx 0.9kg |
Approx 1kg |
Approx 1.5kg |
|||||
Performance specifications |
Performance |
Speed control range |
1 to 5,000 (under the condition that the load torque is less than or equal to the rated torque) |
|||||
Speed fluctuation rate |
During load fluctuation |
±0.01% or less with a load fluctuation between 0 and 100% (at the rated rotation speed) |
||||||
When the voltage of the main circuit fluctuates |
0% at the rated voltage ±10% (at the rated rotation speed) |
|||||||
When the ambient temperature fluctuates |
±0.1% or less when the ambient temperature is between 0 and +50°C (at the rated rotation speed) |
|||||||
Torque control accuracy (reproducibility) |
±1% |
|||||||
Speed frequency response |
1.6 kHz (when JL = JM) * JL: load moment of inertia (motor axis conversion), JM: motor moment of inertia |
|||||||
Dynamic brake |
Built-in |
|||||||
Analogue monitor output for observation |
Monitor output such as motor rotation speed and torque instruction for observations, number of built-in channels: 2 |
|||||||
Regenerative resistor |
Built-in regenerative resistor |
None |
Present (40 W) |
|||||
External regenerative resistor |
OP-84399 (220 W*2) |
|||||||
Display function |
Access window |
Status monitor, parameter settings, calibration, etc. |
||||||
CHARGE display LED |
CHARGE LED (orange) for checking the main circuit power supply input |
|||||||
Status |
Servo on, instruction input in progress, warning |
|||||||
Communication function |
USB communication |
Function |
Status display, parameter settings, calibration, etc. |
|||||
Connection device |
PC |
|||||||
Protection function |
Overcurrent, overvoltage, insufficient voltage, overload, regeneration error, etc. |
|||||||
Other functions |
Auto calibration, absolute position system, etc. |
|||||||
I/O specifications |
Pulse/Analogue input type |
Control I/O |
Input signal: Number of channels |
13ch |
||||
Output signal: Number of channels |
5ch |
|||||||
Output signal: Function |
Alarm (ALARM), operation preparation complete (RDY), in position (INPOS), speed matching (VCMP), electromagnetic brake timing (BRAKE), torque control in progress (TLM), speed control in progress (VLM), warning (WARN), zero-speed detection (ZSP), near posi |
|||||||
Encoder division pulse output |
A-phase (A+, A-), B-phase (B+, B-), Z-phase (Z+, Z-): line-driver output;*3 Z-phase (ZOC): open-collector output; number of division pulses: 1.6 Mpps maximum (6.4 MHz when 2-phase 4× selected)*4 |
|||||||
Position control |
Pulse string input: Command pulse format |
Sign + pulse wave, 2-pulse, A-phase + B-phase * Positive and negative logic can be selected for each shape. |
||||||
Pulse string input: Input format |
Line driver,*3 open collector |
|||||||
Pulse string input: Input frequency |
Line driver single-phase: 4 MHz, phase difference: 4 MHz, open collector: 200 kHz |
|||||||
Speed control |
Analogue input: Command voltage |
Maximum input voltage: ±12 V |
||||||
Analogue input: Input impedance |
Approx 14 kΩ or more |
|||||||
Analogue input: Circuit time constant |
30 µs |
|||||||
Speed selection |
The SPD1, SPD2, and SPD3 signals can be used to select the 1st to 7th setting instruction speeds. |
|||||||
Torque control |
Analogue input: Command voltage |
Maximum input voltage: ±12 V |
||||||
Analogue input: Input impedance |
Approx 14 kΩ or more |
|||||||
Analogue input: Circuit time constant |
16 µs |
|||||||
I/O terminal specifications and wiring |
General-purpose input (DI-1) |
Maximum input voltage |
26.4 VDC |
|||||
Input rated voltage |
24 VDC (5mA) |
|||||||
Minimum ON voltage |
19 VDC |
|||||||
Maximum OFF current |
0.1mA |
|||||||
Common ground |
Common (MECHATROLINK-II type servo amplifiers only have positive commons.) |
|||||||
General-purpose output (DO-1) |
Output |
Open-collector output |
||||||
Rated load |
30 VDC (30mA) |
|||||||
Leakage current (at OFF) |
0.1mA |
|||||||
Residual voltage (at ON) |
1.6 VDC or less |
|||||||
Common ground |
Common |
|||||||
2-wire method compatible input (DI-2) |
Maximum input voltage |
26.4 VDC |
||||||
Input rated voltage |
24 VDC (9mA) |
|||||||
Minimum ON voltage |
19 VDC |
|||||||
Maximum OFF current |
1.5mA |
|||||||
Common ground |
Common (MECHATROLINK-II type servo amplifiers only have positive commons.) |
|||||||
2-wire method compatible high-speed input (DI-3) |
Maximum input voltage |
― |
||||||
Input rated voltage |
||||||||
Minimum ON voltage |
||||||||
Maximum OFF current |
||||||||
Z phase open-collector output (DO-2) |
Output |
Non-isolated open-collector output |
||||||
Rated load |
30 VDC (30mA) |
|||||||
Leakage current (at OFF) |
0.1mA |
|||||||
Residual voltage (at ON) |
1.2 VDC or less |
|||||||
Common ground |
Non-isolated |
|||||||
Output frequency |
50kHz |
|||||||
Analogue input (AI) |
Input level |
±12 VDC |
||||||
Accuracy |
±0.02% (V-REF), ±1% (T-REF) |
|||||||
Circuit input filter |
30 µs (V-REF), 16 µs (T-REF) |
|||||||
Pulse input (DI-P) |
Maximum input voltage |
Differential line-driver |
Corresponds to AM26C31 |
|||||
Open-collector (R1 resistance value): 2.2 kΩ |
30 VDC*5 |
|||||||
Open-collector (R1 resistance value): 1 kΩ |
15 VDC*6 |
|||||||
Open-collector (R1 resistance value): 180 kΩ |
6.25 VDC*7 |
|||||||
Input rated voltage |
Differential line-driver |
Corresponds to AM26C31 |
||||||
Open-collector (R1 resistance value): 2.2 kΩ |
24 VDC*8 |
|||||||
Open-collector (R1 resistance value): 1 kΩ |
12 VDC*6 |
|||||||
Open-collector (R1 resistance value): 180 kΩ |
5 VDC*7 |
|||||||
Minimum ON voltage |
Differential line-driver |
Corresponds to AM26C31 |
||||||
Open-collector (R1 resistance value): 2.2 kΩ |
18.3V*6 |
|||||||
Open-collector (R1 resistance value): 1 kΩ |
9.9V*6 |
|||||||
Open-collector (R1 resistance value): 180 kΩ |
4.2V*6 |
|||||||
Maximum OFF current |
Differential line-driver |
Corresponds to AM26C31 |
||||||
Open-collector (R1 resistance value) recommended input current |
0.1 mA*6 |
|||||||
Common ground |
Differential line-driver |
Independent (non-isolated) |
||||||
Open-collector (R1 resistance value) recommended input current |
Common*9 |
|||||||
Response frequency |
Differential line-driver |
Single-phase: 4 MHz, phase difference: 4 MHz |
||||||
Open-collector (R1 resistance value) recommended input current |
200kHz*6 |
|||||||
Encoder output (DO-E) |
Output |
Differential line-driver output |
||||||
Output voltage |
Corresponds to AM26C31 |
|||||||
Common ground |
Independent (non-isolated) |
|||||||
Output frequency |
Phase difference: 1.6 Mpps (after 4×: 6.4 MHz) |
|||||||
*1 When used with the amount of current listed above, the duration of the rush current is 20 ms or lower. |
Model |
SV-100P2 |
SV-150P2 |
SV-200P2 |
SV-300P2 |
SV-500P2 |
|||
Image |
|
|
|
|
|
|||
Power supply/current capacity and power loss |
Maximum applicable motor capacity Single-phase 100 VAC |
― |
||||||
Maximum applicable motor capacity Three-phase 200 VAC |
1.0kW |
1.5kW |
2.0kW |
3.0kW |
5.0kW |
|||
Maximum applicable motor capacity Single-phase 200 VAC |
― |
|||||||
Power capacity (VA) per amplifier Single-phase 100 VAC |
||||||||
Power capacity (VA) per amplifier Three-phase 200 VAC |
2300 VA |
3200 VA |
4000 VA |
5900 VA |
7500 VA |
|||
Power capacity (VA) per amplifier Single-phase 200 VAC |
― |
|||||||
Output current Continuous |
Single-phase 100 VAC |
|||||||
Three-phase 200 VAC |
7.6 Arms |
11.6 Arms |
18.5 Arms |
19.6 Arms |
32.9 Arms |
|||
Single-phase 200 VAC |
― |
|||||||
Output current Maximum |
Single-phase 100 VAC |
|||||||
Three-phase 200 VAC |
17 Arms |
28 Arms |
42 Arms |
56 Arms |
84 Arms |
|||
Single-phase 200 VAC |
― |
|||||||
Main circuit power loss Single-phase 100 VAC |
||||||||
Main circuit power loss Three-phase 200 VAC |
53.6 W |
65.8 W |
111.9 W |
113.8 W |
263.7 W |
|||
Main circuit power loss Single-phase 200 VAC |
― |
|||||||
Built-in regenerative resistor power loss Single-phase 100 VAC |
||||||||
Built-in regenerative resistor power loss Three-phase 200 VAC |
8 W |
10 W |
16 W |
36 W |
||||
Built-in regenerative resistor power loss Single-phase 200 VAC |
― |
|||||||
Control circuit power loss Single-phase 100 VAC |
||||||||
Control circuit power loss Three-phase 200 VAC |
17 W |
22 W |
27 W |
|||||
Control circuit power loss Single-phase 200 VAC |
― |
|||||||
Total power loss Single-phase 100 VAC |
||||||||
Total power loss Three-phase 200 VAC |
78.6 W |
97.8 W |
149.9 W |
151.8 W |
326.7 W |
|||
Total power loss Single-phase 200 VAC |
― |
|||||||
Input rated current |
Main circuit Single-phase 100 VAC |
|||||||
Main circuit Three-phase 200 VAC |
6 Arms |
7.3 Arms |
9.7 Arms |
15 Arms |
25 Arms |
|||
Main circuit Single-phase 200 VAC |
― |
|||||||
Control circuit Single-phase 100 VAC |
||||||||
Control circuit Three-phase 200 VAC |
0.2 Arms |
0.25 Arms |
0.3 Arms |
|||||
Control circuit Single-phase 200 VAC |
― |
|||||||
Rush current |
Main circuit Single-phase 100 VAC |
―*1 |
||||||
Main circuit Three-phase 200 VAC |
33 A*1 |
65.5 A*1 |
||||||
Main circuit Single-phase 200 VAC |
―*1 |
|||||||
Control circuit Single-phase 100 VAC |
||||||||
Control circuit Three-phase 200 VAC |
33 A*1 |
|||||||
Control circuit Single-phase 200 VAC |
―*1 |
|||||||
General specifications |
Type |
For 200 V |
||||||
Capacity |
1.0kW |
1.5kW |
2.0kW |
3.0kW |
5.0kW |
|||
Input power supply |
Voltage/frequency |
Main circuit |
3-phase 200 to 230 VAC, 50/60 Hz, 270 to 320 VDC |
|||||
Control circuit |
Single-phase 200 to 230 VAC, 50/60 Hz |
|||||||
Main circuit/control circuit |
Allowable voltage fluctuation |
170 to 253 VAC |
||||||
Allowable frequency fluctuation |
±5% or less |
|||||||
Allowable instantaneous outage time |
Main circuit |
Full-stop (100% down): 0.5 cycles, half-stop (50% down): 1 cycle |
Full (100% down): 0.5 cycle, Partial (50% down): 1 cycle |
Full-stop (100% down): 0.5 cycles, half-stop (50% down): 1 cycle |
||||
Control circuit |
Approx 100ms |
|||||||
Overvoltage category |
III |
|||||||
Control method |
3-phase full-wave rectification, IGBT, PWM control, sine wave current drive method |
3-phase full-wave rectification, IGBT PWM control, sinusoidal current drive system |
3-phase full-wave rectification, IGBT, PWM control, sine wave current drive method |
|||||
Feedback |
20-bit serial encoder (incremental, absolute) communication |
20-bit serial encoder (incremental, absolute) communication |
||||||
Operating environment |
Operating ambient temperature |
0 to +55°C (no freezing) |
||||||
Ambient storage temperature |
-20 to +70°C (no freezing) |
|||||||
Ambient operating/storage humidity |
90%RH or less (no condensation) |
|||||||
Vibration resistance |
4.9 m/s2 (conforms to JIS C 60068-2-6) |
|||||||
Shock resistance |
19.6 m/s2 (conforms to JIS C 60068-2-27) |
|||||||
Operating atmosphere (enclosure rating/pollution degree) |
Pollution degree: 2 (within a control panel that has a rating of IP54 or higher), however, · No corrosive or flammable gas present · A location that is not subject to water, oil, or drugs · No dust present |
|||||||
Altitude |
1,000 m or less above sea level |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL508C, CSA C22.2 number 14 |
UL508C, and CSA C22.2 No.14 |
UL508C, CSA C22.2 number 14 |
||||
CE marking |
Low-voltage directive |
EN50178 |
||||||
EMI |
EN55011 Class A, EN61800-3 |
|||||||
EMS |
EN61800-3, EN61000-6-2 |
|||||||
North American EMI standards |
FCC Part 15 B, ICES-003, Class A |
FCC Part15 B, ICES-003. Class A |
FCC Part 15 B, ICES-003, Class A |
FCC Part15 B, ICES-003. Class A |
||||
Structure |
Type |
Base mounting attachment |
||||||
Protection |
Open, forced |
|||||||
Lowest insulation resistance value |
1 MΩ or more, tested with a 500 VDC megger |
|||||||
Insulation withstand voltage |
1,500 VAC or more (between the primary side and the earth terminal), 1,800 VAC or more (between the primary side and the secondary side) |
|||||||
Weight |
Approx 1.5kg |
Approx 2.4kg |
Approx 2.9kg |
Approx 4.7kg |
||||
Performance specifications |
Performance |
Speed control range |
1 to 5,000 (under the condition that the load torque is less than or equal to the rated torque) |
|||||
Speed fluctuation rate |
During load fluctuation |
±0.01% or less with a load fluctuation between 0 and 100% (at the rated rotation speed) |
||||||
When the voltage of the main circuit fluctuates |
0% at the rated voltage ±10% (at the rated rotation speed) |
|||||||
When the ambient temperature fluctuates |
±0.1% or less when the ambient temperature is between 0 and +50°C (at the rated rotation speed) |
|||||||
Torque control accuracy (reproducibility) |
±1% |
|||||||
Speed frequency response |
1.6 kHz (when JL = JM) * JL: load moment of inertia (motor axis conversion), JM: motor moment of inertia |
|||||||
Dynamic brake |
Built-in |
|||||||
Analogue monitor output for observation |
Monitor output such as motor rotation speed and torque instruction for observations, number of built-in channels: 2 |
|||||||
Regenerative resistor |
Built-in regenerative resistor |
Present (40 W) |
Present (50 W) |
Present (80 W) |
Present (180 W) |
|||
External regenerative resistor |
OP-84399 (220 W*2) |
OP-87073 (220 W*2) |
None*10 |
|||||
Display function |
Access window |
Status monitor, parameter settings, calibration, etc. |
||||||
CHARGE display LED |
CHARGE LED (orange) for checking the main circuit power supply input |
|||||||
Status |
Servo on, instruction input in progress, warning |
|||||||
Communication function |
USB communication |
Function |
Status display, parameter settings, calibration, etc. |
|||||
Connection device |
PC |
|||||||
Protection function |
Overcurrent, overvoltage, insufficient voltage, overload, regeneration error, etc. |
|||||||
Other functions |
Auto calibration, absolute position system, etc. |
|||||||
I/O specifications |
MECHATROLINK-II type |
Control I/O |
Input signal: Number of channels |
― |
||||
Input signal: Function |
||||||||
Output signal: Number of channels |
||||||||
Output signal: Function |
||||||||
Encoder division pulse output |
||||||||
Pulse/Analogue input type |
Control I/O |
Input signal: Number of channels |
13ch |
|||||
Output signal: Number of channels |
5ch |
|||||||
Output signal: Function |
Alarm (ALARM), operation preparation complete (RDY), in position (INPOS), speed matching (VCMP), electromagnetic brake timing (BRAKE), torque control in progress (TLM), speed control in progress (VLM), warning (WARN), zero-speed detection (ZSP), near posi |
|||||||
Encoder division pulse output |
A-phase (A+, A-), B-phase (B+, B-), Z-phase (Z+, Z-): line-driver output;*3 Z-phase (ZOC): open-collector output; number of division pulses: 1.6 Mpps maximum (6.4 MHz when 2-phase 4× selected)*4 |
|||||||
Position control |
Pulse string input: Command pulse format |
Sign + pulse wave, 2-pulse, A-phase + B-phase * Positive and negative logic can be selected for each shape. |
||||||
Pulse string input: Input format |
Line driver,*3 open collector |
|||||||
Pulse string input: Input frequency |
Line driver single-phase: 4 MHz, phase difference: 4 MHz, open collector: 200 kHz |
|||||||
Speed control |
Analogue input: Command voltage |
Maximum input voltage: ±12 V |
||||||
Analogue input: Input impedance |
Approx 14 kΩ or more |
|||||||
Analogue input: Circuit time constant |
30 µs |
|||||||
Speed selection |
The SPD1, SPD2, and SPD3 signals can be used to select the 1st to 7th setting instruction speeds. |
|||||||
Torque control |
Analogue input: Command voltage |
Maximum input voltage: ±12 V |
||||||
Analogue input: Input impedance |
Approx 14 kΩ or more |
|||||||
Analogue input: Circuit time constant |
16 µs |
|||||||
Communication specifications (MECHATROLINK-II type only) |
MECHATROLINK communication |
Station address |
― |
|||||
Transmission speed |
MECHATROLINK-II |
|||||||
MECHATROLINK-I |
||||||||
Transmission frequency |
MECHATROLINK-II |
|||||||
MECHATROLINK-I |
||||||||
Transmission byte number |
MECHATROLINK-II |
|||||||
MECHATROLINK-I |
||||||||
Command method |
Operation specifications |
|||||||
Command input |
||||||||
I/O terminal specifications and wiring |
General-purpose input (DI-1) |
Maximum input voltage |
26.4 VDC |
|||||
Input rated voltage |
24 VDC (5mA) |
|||||||
Minimum ON voltage |
19 VDC |
|||||||
Maximum OFF current |
0.1mA |
|||||||
Common ground |
Common (MECHATROLINK-II type servo amplifiers only have positive commons.) |
|||||||
General-purpose output (DO-1) |
Output |
Open-collector output |
||||||
Rated load |
30 VDC (30mA) |
|||||||
Leakage current (at OFF) |
0.1mA |
|||||||
Residual voltage (at ON) |
1.6 VDC or less |
|||||||
Common ground |
Common |
|||||||
2-wire method compatible input (DI-2) |
Maximum input voltage |
26.4 VDC |
||||||
Input rated voltage |
24 VDC (9mA) |
|||||||
Minimum ON voltage |
19 VDC |
|||||||
Maximum OFF current |
1.5mA |
|||||||
Common ground |
Common (MECHATROLINK-II type servo amplifiers only have positive commons.) |
|||||||
2-wire method compatible high-speed input (DI-3) |
Maximum input voltage |
― |
||||||
Input rated voltage |
||||||||
Minimum ON voltage |
||||||||
Maximum OFF current |
||||||||
Common ground |
||||||||
Z phase open-collector output (DO-2) |
Output |
Non-isolated open-collector output |
||||||
Rated load |
30 VDC (30mA) |
|||||||
Leakage current (at OFF) |
0.1mA |
|||||||
Residual voltage (at ON) |
1.2 VDC or less |
|||||||
Common ground |
Non-isolated |
|||||||
Output frequency |
50kHz |
|||||||
Analogue input (AI) |
Input level |
±12 VDC |
||||||
Accuracy |
±0.02% (V-REF), ±1% (T-REF) |
|||||||
Circuit input filter |
30 µs (V-REF), 16 µs (T-REF) |
|||||||
Pulse input (DI-P) |
Maximum input voltage |
Differential line-driver |
Corresponds to AM26C31 |
|||||
Open-collector (R1 resistance value): 2.2 kΩ |
30 VDC*5 |
|||||||
Open-collector (R1 resistance value): 1 kΩ |
15 VDC*6 |
|||||||
Open-collector (R1 resistance value): 180 kΩ |
6.25 VDC*7 |
|||||||
Input rated voltage |
Differential line-driver |
Corresponds to AM26C31 |
||||||
Open-collector (R1 resistance value): 2.2 kΩ |
24 VDC*8 |
|||||||
Open-collector (R1 resistance value): 1 kΩ |
12 VDC*6 |
|||||||
Open-collector (R1 resistance value): 180 kΩ |
5 VDC*7 |
|||||||
Minimum ON voltage |
Differential line-driver |
Corresponds to AM26C31 |
||||||
Open-collector (R1 resistance value): 2.2 kΩ |
18.3V*6 |
|||||||
Open-collector (R1 resistance value): 1 kΩ |
9.9V*6 |
|||||||
Open-collector (R1 resistance value): 180 kΩ |
4.2V*6 |
|||||||
Maximum OFF current |
Differential line-driver |
Corresponds to AM26C31 |
||||||
Open-collector (R1 resistance value) recommended input current |
0.1 mA*6 |
|||||||
Common ground |
Differential line-driver |
Independent (non-isolated) |
||||||
Open-collector (R1 resistance value) recommended input current |
Common*9 |
|||||||
Response frequency |
Differential line-driver |
Single-phase: 4 MHz, phase difference: 4 MHz |
||||||
Open-collector (R1 resistance value) recommended input current |
200kHz*6 |
|||||||
Encoder output (DO-E) |
Output |
Differential line-driver output |
||||||
Output voltage |
Corresponds to AM26C31 |
|||||||
Common ground |
Independent (non-isolated) |
|||||||
Output frequency |
Phase difference: 1.6 Mpps (after 4×: 6.4 MHz) |
|||||||
*1 When used with the amount of current listed above, the duration of the rush current is 20 ms or lower. |
Model |
SV-010P1 |
SV-020P1 |
SV-040P1 |
|||
Image |
|
|
|
|||
Power supply/current capacity and power loss |
Maximum applicable motor capacity Single-phase 100 VAC |
100 W |
200 W |
400 W |
||
Maximum applicable motor capacity Three-phase 200 VAC |
― |
|||||
Maximum applicable motor capacity Single-phase 200 VAC |
||||||
Power capacity (VA) per amplifier Single-phase 100 VAC |
300 VA |
700 VA |
1400 VA |
|||
Power capacity (VA) per amplifier Three-phase 200 VAC |
― |
|||||
Power capacity (VA) per amplifier Single-phase 200 VAC |
||||||
Output current Continuous |
Single-phase 100 VAC |
0.91 Arms |
2.1 Arms |
2.8 Arms |
||
Three-phase 200 VAC |
― |
|||||
Single-phase 200 VAC |
||||||
Output current Maximum |
Single-phase 100 VAC |
2.9 Arms |
6.5 Arms |
9.3 Arms |
||
Three-phase 200 VAC |
― |
|||||
Single-phase 200 VAC |
||||||
Main circuit power loss Single-phase 100 VAC |
7.8 W |
14.4 W |
25.6 W |
|||
Control circuit power loss Single-phase 100 VAC |
17 W |
|||||
Control circuit power loss Three-phase 200 VAC |
― |
|||||
Control circuit power loss Single-phase 200 VAC |
||||||
Total power loss Single-phase 100 VAC |
24.8 W |
31.4 W |
42.6 W |
|||
Total power loss Three-phase 200 VAC |
― |
|||||
Total power loss Single-phase 200 VAC |
||||||
Input rated current |
Main circuit Single-phase 100 VAC |
2.5 Arms |
5 Arms |
10 Arms |
||
Main circuit Three-phase 200 VAC |
1 Arms |
― |
3 Arms |
|||
Main circuit Single-phase 200 VAC |
2 Arms |
3 Arms |
5 Arms |
|||
Control circuit Single-phase 100 VAC |
0.38 Arms |
|||||
Control circuit Three-phase 200 VAC |
― |
|||||
Control circuit Single-phase 200 VAC |
||||||
Rush current |
Main circuit Single-phase 100 VAC |
16.5 A*1 |
||||
Main circuit Three-phase 200 VAC |
33 A*1 |
33*1 |
||||
Main circuit Single-phase 200 VAC |
33 A*1 |
|||||
Control circuit Single-phase 100 VAC |
35 A*1 |
|||||
Control circuit Three-phase 200 VAC |
―*1 |
|||||
Control circuit Single-phase 200 VAC |
||||||
General specifications |
Type |
For 100 V |
||||
Capacity |
100W |
200W |
400W |
|||
Input power supply |
Voltage/frequency |
Main circuit |
Single-phase 100 to 115 VAC, 50/60 Hz |
|||
Control circuit |
||||||
Main circuit/control circuit |
Allowable voltage fluctuation |
85 to 127 VAC |
||||
Allowable frequency fluctuation |
±5% or less |
|||||
Allowable instantaneous outage time |
Main circuit |
Full-stop (100% down): 0.5 cycles, half-stop (50% down): 1 cycle |
||||
Control circuit |
Approx 65ms |
|||||
Overvoltage category |
III |
|||||
Control method |
3-phase full-wave rectification, IGBT, PWM control, sine wave current drive method |
|||||
Feedback |
20-bit serial encoder (incremental, absolute) communication |
|||||
Operating environment |
Operating ambient temperature |
0 to +55°C (no freezing) |
||||
Ambient storage temperature |
-20 to +70°C (no freezing) |
|||||
Ambient operating/storage humidity |
90%RH or less (no condensation) |
|||||
Vibration resistance |
4.9 m/s2 (conforms to JIS C 60068-2-6) |
|||||
Shock resistance |
19.6 m/s2 (conforms to JIS C 60068-2-27) |
|||||
Operating atmosphere (enclosure rating/pollution degree) |
Pollution degree: 2 (within a control panel that has a rating of IP54 or higher), however, · No corrosive or flammable gas present · A location that is not subject to water, oil, or drugs · No dust present |
|||||
Altitude |
1,000 m or less above sea level |
|||||
Approved standards |
UL/CSA standards |
UL508C, CSA C22.2 number 14 |
||||
CE marking |
Low-voltage directive |
EN50178 |
||||
EMI |
EN55011 Class A, EN61800-3 |
|||||
EMS |
EN61800-3, EN61000-6-2 |
|||||
North American EMI standards |
FCC Part 15 B, ICES-003, Class A |
|||||
Structure |
Type |
Base mounting attachment |
||||
Protection |
Open, forced |
|||||
Lowest insulation resistance value |
1 MΩ or more, tested with a 500 VDC megger |
|||||
Insulation withstand voltage |
1,500 VAC or more (between the primary side and the earth terminal), 1,800 VAC or more (between the primary side and the secondary side) |
|||||
Weight |
Approx 1.1kg |
Approx 1.5kg |
||||
Performance specifications |
Performance |
Speed control range |
1 to 5,000 (under the condition that the load torque is less than or equal to the rated torque) |
|||
Speed fluctuation rate |
During load fluctuation |
±0.01% or less with a load fluctuation between 0 and 100% (at the rated rotation speed) |
||||
When the voltage of the main circuit fluctuates |
0% at the rated voltage ±10% (at the rated rotation speed) |
|||||
When the ambient temperature fluctuates |
±0.1% or less when the ambient temperature is between 0 and +50°C (at the rated rotation speed) |
|||||
Torque control accuracy (reproducibility) |
±1% |
|||||
Speed frequency response |
1.6 kHz (when JL = JM) * JL: load moment of inertia (motor axis conversion), JM: motor moment of inertia |
|||||
Dynamic brake |
Built-in |
|||||
Analogue monitor output for observation |
Monitor output such as motor rotation speed and torque instruction for observations, number of built-in channels: 2 |
|||||
Regenerative resistor |
Built-in regenerative resistor |
None |
||||
External regenerative resistor |
OP-84399 (220 W*2) |
|||||
Display function |
Access window |
Status monitor, parameter settings, calibration, etc. |
||||
CHARGE display LED |
CHARGE LED (orange) for checking the main circuit power supply input |
|||||
Status |
Servo on, instruction input in progress, warning |
|||||
Communication function |
USB communication |
Function |
Status display, parameter settings, calibration, etc. |
|||
Connection device |
PC |
|||||
Protection function |
Overcurrent, overvoltage, insufficient voltage, overload, regeneration error, etc. |
|||||
Other functions |
Auto calibration, absolute position system, etc. |
|||||
I/O specifications |
Pulse/Analogue input type |
Control I/O |
Input signal: Number of channels |
13ch |
||
Output signal: Number of channels |
5ch |
|||||
Output signal: Function |
Alarm (ALARM), operation preparation complete (RDY), in position (INPOS), speed matching (VCMP), electromagnetic brake timing (BRAKE), torque control in progress (TLM), speed control in progress (VLM), warning (WARN), zero-speed detection (ZSP), near posi |
|||||
Encoder division pulse output |
A-phase (A+, A-), B-phase (B+, B-), Z-phase (Z+, Z-): line-driver output;*3 Z-phase (ZOC): open-collector output; number of division pulses: 1.6 Mpps maximum (6.4 MHz when 2-phase 4× selected)*4 |
|||||
Position control |
Pulse string input: Command pulse format |
Sign + pulse wave, 2-pulse, A-phase + B-phase * Positive and negative logic can be selected for each shape. |
||||
Pulse string input: Input format |
Line driver,*3 open collector |
|||||
Pulse string input: Input frequency |
Line driver single-phase: 4 MHz, phase difference: 4 MHz, open collector: 200 kHz |
|||||
Speed control |
Analogue input: Command voltage |
Maximum input voltage: ±12 V |
||||
Analogue input: Input impedance |
Approx 14 kΩ or more |
|||||
Analogue input: Circuit time constant |
30 µs |
|||||
Speed selection |
The SPD1, SPD2, and SPD3 signals can be used to select the 1st to 7th setting instruction speeds. |
|||||
Torque control |
Analogue input: Command voltage |
Maximum input voltage: ±12 V |
||||
Analogue input: Input impedance |
Approx 14 kΩ or more |
|||||
Analogue input: Circuit time constant |
16 µs |
|||||
I/O terminal specifications and wiring |
General-purpose input (DI-1) |
Maximum input voltage |
26.4 VDC |
|||
Input rated voltage |
24 VDC (5mA) |
|||||
Minimum ON voltage |
19 VDC |
|||||
Maximum OFF current |
0.1mA |
|||||
Common ground |
Common (MECHATROLINK-II type servo amplifiers only have positive commons.) |
|||||
General-purpose output (DO-1) |
Output |
Open-collector output |
||||
Rated load |
30 VDC (30mA) |
|||||
Leakage current (at OFF) |
0.1mA |
|||||
Residual voltage (at ON) |
1.6 VDC or less |
|||||
Common ground |
Common |
|||||
2-wire method compatible input (DI-2) |
Maximum input voltage |
26.4 VDC |
||||
Input rated voltage |
24 VDC (9mA) |
|||||
Minimum ON voltage |
19 VDC |
|||||
Maximum OFF current |
1.5mA |
|||||
Common ground |
Common (MECHATROLINK-II type servo amplifiers only have positive commons.) |
|||||
2-wire method compatible high-speed input (DI-3) |
Maximum input voltage |
― |
||||
Input rated voltage |
||||||
Minimum ON voltage |
||||||
Maximum OFF current |
||||||
Common ground |
||||||
Z phase open-collector output (DO-2) |
Output |
Non-isolated open-collector output |
||||
Rated load |
30 VDC (30mA) |
|||||
Leakage current (at OFF) |
0.1mA |
|||||
Residual voltage (at ON) |
1.2 VDC or less |
|||||
Common ground |
Non-isolated |
|||||
Output frequency |
50kHz |
|||||
Analogue input (AI) |
Input level |
±12 VDC |
||||
Accuracy |
±0.02% (V-REF), ±1% (T-REF) |
|||||
Circuit input filter |
30 µs (V-REF), 16 µs (T-REF) |
|||||
Pulse input (DI-P) |
Maximum input voltage |
Differential line-driver |
Corresponds to AM26C31 |
|||
Open-collector (R1 resistance value): 2.2 kΩ |
30 VDC*5 |
|||||
Open-collector (R1 resistance value): 1 kΩ |
15 VDC*6 |
|||||
Open-collector (R1 resistance value): 180 kΩ |
6.25 VDC*7 |
|||||
Input rated voltage |
Differential line-driver |
Corresponds to AM26C31 |
||||
Open-collector (R1 resistance value): 2.2 kΩ |
24 VDC*8 |
|||||
Open-collector (R1 resistance value): 1 kΩ |
12 VDC*6 |
|||||
Open-collector (R1 resistance value): 180 kΩ |
5 VDC*7 |
|||||
Minimum ON voltage |
Differential line-driver |
Corresponds to AM26C31 |
||||
Open-collector (R1 resistance value): 2.2 kΩ |
18.3V*6 |
|||||
Open-collector (R1 resistance value): 1 kΩ |
9.9V*6 |
|||||
Open-collector (R1 resistance value): 180 kΩ |
4.2V*6 |
|||||
Maximum OFF current |
Differential line-driver |
Corresponds to AM26C31 |
||||
Open-collector (R1 resistance value) recommended input current |
0.1 mA*6 |
|||||
Common ground |
Differential line-driver |
Independent (non-isolated) |
||||
Open-collector (R1 resistance value) recommended input current |
Common*9 |
|||||
Response frequency |
Differential line-driver |
Single-phase: 4 MHz, phase difference: 4 MHz |
||||
Open-collector (R1 resistance value) recommended input current |
200kHz*6 |
|||||
Encoder output (DO-E) |
Output |
Differential line-driver output |
||||
Output voltage |
Corresponds to AM26C31 |
|||||
Common ground |
Independent (non-isolated) |
|||||
Output frequency |
Phase difference: 1.6 Mpps (after 4×: 6.4 MHz) |
|||||
*1 When used with the amount of current listed above, the duration of the rush current is 20 ms or lower. |
Model |
SV-005L2 |
SV-010L2 |
SV-020L2 |
SV-040L2 |
SV-075L2 |
|||
Image |
|
|
|
|
|
|||
Power supply/current capacity and power loss |
Maximum applicable motor capacity Single-phase 100 VAC |
― |
||||||
Maximum applicable motor capacity Three-phase 200 VAC |
50 W |
100 W |
200 W |
400 W |
750 W |
|||
Maximum applicable motor capacity Single-phase 200 VAC |
||||||||
Power capacity (VA) per amplifier Single-phase 100 VAC |
― |
|||||||
Power capacity (VA) per amplifier Three-phase 200 VAC |
200 VA |
300 VA |
600 VA |
1000 VA |
1600 VA |
|||
Power capacity (VA) per amplifier Single-phase 200 VAC |
700 VA |
1200 VA |
1900 VA |
|||||
Output current Continuous |
Single-phase 100 VAC |
― |
||||||
Three-phase 200 VAC |
0.66 Arms |
0.91 Arms |
1.6 Arms |
2.8 Arms |
5.5 Arms |
|||
Single-phase 200 VAC |
||||||||
Output current Maximum |
Single-phase 100 VAC |
― |
||||||
Three-phase 200 VAC |
2.1 Arms |
2.9 Arms |
5.8 Arms |
9.3 Arms |
16.9 Arms |
|||
Single-phase 200 VAC |
||||||||
Main circuit power loss Single-phase 100 VAC |
― |
|||||||
Main circuit power loss Three-phase 200 VAC |
5.1 W |
7.3 W |
13.5 W |
24 W |
43.8 W |
|||
Main circuit power loss Single-phase 200 VAC |
5.2 W |
7.4 W |
13.7 W |
24.9 W |
52.7 W |
|||
Built-in regenerative resistor power loss Single-phase 100 VAC |
― |
|||||||
Built-in regenerative resistor power loss Three-phase 200 VAC |
― |
8 W |
||||||
Built-in regenerative resistor power loss Single-phase 200 VAC |
||||||||
Control circuit power loss Single-phase 100 VAC |
― |
|||||||
Control circuit power loss Three-phase 200 VAC |
17 W |
|||||||
Control circuit power loss Single-phase 200 VAC |
||||||||
Total power loss Single-phase 100 VAC |
― |
|||||||
Total power loss Three-phase 200 VAC |
22.1 W |
24.3 W |
30.5 W |
41 W |
68.8 W |
|||
Total power loss Single-phase 200 VAC |
22.2 W |
24.4 W |
30.7 W |
41.9 W |
77.7 W |
|||
Input rated current |
Main circuit Single-phase 100 VAC |
― |
||||||
Main circuit Three-phase 200 VAC |
1 Arms |
2 Arms |
3 Arms |
6 Arms |
||||
Main circuit Single-phase 200 VAC |
2 Arms |
3 Arms |
5 Arms |
9 Arms |
||||
Control circuit Single-phase 100 VAC |
― |
|||||||
Control circuit Three-phase 200 VAC |
0.2 Arms |
|||||||
Control circuit Single-phase 200 VAC |
||||||||
Rush current |
Main circuit Single-phase 100 VAC |
―*1 |
||||||
Main circuit Three-phase 200 VAC |
33 A*1 |
|||||||
Main circuit Single-phase 200 VAC |
||||||||
Control circuit Single-phase 100 VAC |
―*1 |
|||||||
Control circuit Three-phase 200 VAC |
70 A*1 |
33 A*1 |
||||||
Control circuit Single-phase 200 VAC |
||||||||
General specifications |
Type |
For 200 V |
||||||
Capacity |
50W |
100W |
200W |
400W |
750W |
|||
Input power supply |
Voltage/frequency |
Main circuit |
3-phase (or single-phase) 200 to 230 VAC, 50/60 Hz, 270 to 320 VDC |
|||||
Control circuit |
Single-phase 200 to 230 VAC, 50/60 Hz |
|||||||
Main circuit/control circuit |
Allowable voltage fluctuation |
170 to 253 VAC |
||||||
Allowable frequency fluctuation |
±5% or less |
|||||||
Allowable instantaneous outage time |
Main circuit |
Full-stop (100% down): 0.5 cycles, half-stop (50% down): 1 cycle |
||||||
Control circuit |
Approx 100ms |
|||||||
Overvoltage category |
III |
|||||||
Control method |
3-phase full-wave rectification, IGBT, PWM control, sine wave current drive method |
|||||||
Feedback |
20-bit serial encoder (incremental, absolute) communication |
|||||||
Operating environment |
Operating ambient temperature |
0 to +55°C (no freezing) |
||||||
Ambient storage temperature |
-20 to +70°C (no freezing) |
|||||||
Ambient operating/storage humidity |
90%RH or less (no condensation) |
|||||||
Vibration resistance |
4.9 m/s2 (conforms to JIS C 60068-2-6) |
|||||||
Shock resistance |
19.6 m/s2 (conforms to JIS C 60068-2-27) |
|||||||
Operating atmosphere (enclosure rating/pollution degree) |
Pollution degree: 2 (within a control panel that has a rating of IP54 or higher), however, · No corrosive or flammable gas present · A location that is not subject to water, oil, or drugs · No dust present |
|||||||
Altitude |
1,000 m or less above sea level |
|||||||
Approved standards |
UL/CSA standards |
UL508C, CSA C22.2 number 14 |
||||||
CE marking |
Low-voltage directive |
EN50178 |
||||||
EMI |
EN55011 Class A, EN61800-3 |
|||||||
EMS |
EN61800-3, EN61000-6-2 |
|||||||
North American EMI standards |
FCC Part 15 B, ICES-003, Class A |
|||||||
Structure |
Type |
Base mounting attachment |
||||||
Protection |
Open, forced |
|||||||
Lowest insulation resistance value |
1 MΩ or more, tested with a 500 VDC megger |
|||||||
Insulation withstand voltage |
1,500 VAC or more (between the primary side and the earth terminal), 1,800 VAC or more (between the primary side and the secondary side) |
|||||||
Weight |
Approx 0.9kg |
Approx 1kg |
Approx 1.5kg |
|||||
Performance specifications |
Performance |
Speed control range |
1 to 5,000 (under the condition that the load torque is less than or equal to the rated torque) |
|||||
Speed fluctuation rate |
During load fluctuation |
±0.01% or less with a load fluctuation between 0 and 100% (at the rated rotation speed) |
||||||
When the voltage of the main circuit fluctuates |
0% at the rated voltage ±10% (at the rated rotation speed) |
|||||||
When the ambient temperature fluctuates |
±0.1% or less when the ambient temperature is between 0 and +50°C (at the rated rotation speed) |
|||||||
Torque control accuracy (reproducibility) |
±1% |
|||||||
Speed frequency response |
1.6 kHz (when JL = JM) * JL: load moment of inertia (motor axis conversion), JM: motor moment of inertia |
|||||||
Dynamic brake |
Built-in |
|||||||
Analogue monitor output for observation |
Monitor output such as motor rotation speed and torque instruction for observations, number of built-in channels: 2 |
|||||||
Regenerative resistor |
Built-in regenerative resistor |
None |
Present (40 W) |
|||||
External regenerative resistor |
OP-84399 (220 W*2) |
|||||||
Display function |
Access window |
Status monitor, parameter settings, calibration, etc. |
||||||
CHARGE display LED |
CHARGE LED (orange) for checking the main circuit power supply input |
|||||||
Status |
Servo on, instruction input in progress, warning, MECHATROLINK-II communication in progress |
|||||||
Communication function |
USB communication |
Function |
Status display, parameter settings, calibration, etc. |
|||||
Connection device |
PC |
|||||||
Protection function |
Overcurrent, overvoltage, insufficient voltage, overload, regeneration error, etc. |
|||||||
Other functions |
Auto calibration, absolute position system, etc. |
|||||||
I/O specifications |
MECHATROLINK-II type |
Control I/O |
Input signal: Number of channels |
8CH |
||||
Input signal: Function |
Forced stop (FSTOP), forward rotation side limit switch (LSP), reverse rotation side limit switch (LSN), external latch signals 1 to 3 (EXT1, EXT2, EXT3), forward rotation side torque limit selection (PTL), reverse rotation side torque limit selection (NT |
|||||||
Output signal: Number of channels |
4CH |
|||||||
Output signal: Function |
Alarm (ALARM), operation preparation complete (RDY), in position (INPOS), speed matching (VCMP), electromagnetic brake timing (BRAKE), torque control in progress (TLM), speed control in progress (VLM), warning (WARN), zero-speed detection (ZSP), near posi |
|||||||
Encoder division pulse output |
A-phase (A+, A-), B-phase (B+, B-), Z-phase (Z+, Z-): line-driver output;*3 Z-phase (ZOC): open-collector output; number of division pulses: 1.6 Mpps maximum (6.4 MHz when 2-phase 4× selected)*4 |
|||||||
Pulse/Analogue input type |
Control I/O |
Input signal: Number of channels |
― |
|||||
Input signal: Function |
||||||||
Output signal: Number of channels |
||||||||
Output signal: Function |
||||||||
Encoder division pulse output |
||||||||
Position control |
Pulse string input: Command pulse format |
|||||||
Pulse string input: Input format |
||||||||
Pulse string input: Input frequency |
||||||||
Speed control |
Analogue input: Command voltage |
|||||||
Analogue input: Input impedance |
||||||||
Analogue input: Circuit time constant |
||||||||
Speed selection |
||||||||
Torque control |
Analogue input: Command voltage |
|||||||
Analogue input: Input impedance |
||||||||
Analogue input: Circuit time constant |
||||||||
Communication specifications (MECHATROLINK-II type only) |
MECHATROLINK communication |
Station address |
41H to 5FH (Up to 30 slave stations can be connected. The 10s digit is selected from the access window, and the 1s digit is selected with the rotary switch.) |
|||||
Transmission speed |
MECHATROLINK-II |
10 Mbps (selected from the access window) |
||||||
MECHATROLINK-I |
4 Mbps (selected from the access window) |
|||||||
Transmission frequency |
MECHATROLINK-II |
250 µs, 0.5 ms to 4.0 ms (multiples of 0.5) |
||||||
MECHATROLINK-I |
2ms |
|||||||
Transmission byte number |
MECHATROLINK-II |
17 bytes/station, 32 bytes/station (selected from the access window) |
||||||
MECHATROLINK-I |
17 bytes/station |
|||||||
Command method |
Operation specifications |
Position control, speed control, and torque control performed by way of MECHATROLINK communication |
||||||
Command input |
MECHATROLINK-II communication commands (such as sequence, motion, data setting and reference, monitor, and adjustment) |
|||||||
I/O terminal specifications and wiring |
General-purpose input (DI-1) |
Maximum input voltage |
26.4 VDC |
|||||
Input rated voltage |
24 VDC (5mA) |
|||||||
Minimum ON voltage |
19 VDC |
|||||||
Maximum OFF current |
0.1mA |
|||||||
Common ground |
Common (MECHATROLINK-II type servo amplifiers only have positive commons.) |
|||||||
General-purpose output (DO-1) |
Output |
Open-collector output |
||||||
Rated load |
30 VDC (30mA) |
|||||||
Leakage current (at OFF) |
0.1mA |
|||||||
Residual voltage (at ON) |
1.6 VDC or less |
|||||||
Common ground |
Common |
|||||||
2-wire method compatible input (DI-2) |
Maximum input voltage |
26.4 VDC |
||||||
Input rated voltage |
24 VDC (9mA) |
|||||||
Minimum ON voltage |
19 VDC |
|||||||
Maximum OFF current |
1.5mA |
|||||||
Common ground |
Common (MECHATROLINK-II type servo amplifiers only have positive commons.) |
|||||||
2-wire method compatible high-speed input (DI-3) |
Maximum input voltage |
26.4 VDC |
||||||
Input rated voltage |
24 VDC (11mA) |
|||||||
Minimum ON voltage |
19 VDC |
|||||||
Maximum OFF current |
1.5mA |
|||||||
Common ground |
Common |
|||||||
Z phase open-collector output (DO-2) |
Output |
Non-isolated open-collector output |
||||||
Rated load |
30 VDC (30mA) |
|||||||
Leakage current (at OFF) |
0.1mA |
|||||||
Residual voltage (at ON) |
1.2 VDC or less |
|||||||
Common ground |
Non-isolated |
|||||||
Output frequency |
50kHz |
|||||||
Encoder output (DO-E) |
Output |
Differential line-driver output |
||||||
Output voltage |
Corresponds to AM26C31 |
|||||||
Common ground |
Independent (non-isolated) |
|||||||
Output frequency |
Phase difference: 1.6 Mpps (after 4×: 6.4 MHz) |
|||||||
*1 When used with the amount of current listed above, the duration of the rush current is 20 ms or lower. |
Model |
SV-100L2 |
SV-150L2 |
SV-200L2 |
SV-300L2 |
SV-500L2 |
|||
Image |
|
|
|
|
|
|||
Power supply/current capacity and power loss |
Maximum applicable motor capacity Single-phase 100 VAC |
― |
||||||
Maximum applicable motor capacity Three-phase 200 VAC |
1.0kW |
1.5kW |
2.0kW |
3.0kW |
5.0kW |
|||
Maximum applicable motor capacity Single-phase 200 VAC |
― |
|||||||
Power capacity (VA) per amplifier Single-phase 100 VAC |
||||||||
Power capacity (VA) per amplifier Three-phase 200 VAC |
2300 VA |
3200 VA |
4000 VA |
5900 VA |
7500 VA |
|||
Power capacity (VA) per amplifier Single-phase 200 VAC |
― |
|||||||
Output current Continuous |
Single-phase 100 VAC |
|||||||
Three-phase 200 VAC |
7.6 Arms |
11.6 Arms |
18.5 Arms |
19.6 Arms |
32.9 Arms |
|||
Single-phase 200 VAC |
― |
|||||||
Output current Maximum |
Single-phase 100 VAC |
|||||||
Three-phase 200 VAC |
17 Arms |
28 Arms |
42 Arms |
56 Arms |
84 Arms |
|||
Single-phase 200 VAC |
― |
|||||||
Main circuit power loss Single-phase 100 VAC |
||||||||
Main circuit power loss Three-phase 200 VAC |
53.6 W |
65.8 W |
111.9 W |
113.8 W |
263.7 W |
|||
Main circuit power loss Single-phase 200 VAC |
― |
|||||||
Built-in regenerative resistor power loss Single-phase 100 VAC |
||||||||
Built-in regenerative resistor power loss Three-phase 200 VAC |
8 W |
10 W |
16 W |
36 W |
||||
Built-in regenerative resistor power loss Single-phase 200 VAC |
― |
|||||||
Control circuit power loss Single-phase 100 VAC |
||||||||
Control circuit power loss Three-phase 200 VAC |
17 W |
22 W |
27 W |
|||||
Control circuit power loss Single-phase 200 VAC |
― |
|||||||
Total power loss Single-phase 100 VAC |
||||||||
Total power loss Three-phase 200 VAC |
78.6 W |
97.8 W |
149.9 W |
151.8 W |
326.7 W |
|||
Total power loss Single-phase 200 VAC |
― |
|||||||
Input rated current |
Main circuit Single-phase 100 VAC |
|||||||
Main circuit Three-phase 200 VAC |
6 Arms |
7.3 Arms |
9.7 Arms |
15 Arms |
25 Arms |
|||
Main circuit Single-phase 200 VAC |
― |
|||||||
Control circuit Single-phase 100 VAC |
||||||||
Control circuit Three-phase 200 VAC |
0.2 Arms |
0.25 Arms |
0.3 Arms |
|||||
Control circuit Single-phase 200 VAC |
― |
|||||||
Rush current |
Main circuit Single-phase 100 VAC |
―*1 |
||||||
Main circuit Three-phase 200 VAC |
33 A*1 |
65.5 A*1 |
||||||
Main circuit Single-phase 200 VAC |
―*1 |
|||||||
Control circuit Single-phase 100 VAC |
||||||||
Control circuit Three-phase 200 VAC |
33 A*1 |
|||||||
Control circuit Single-phase 200 VAC |
―*1 |
|||||||
General specifications |
Type |
For 200 V |
||||||
Capacity |
1.0kW |
1.5kW |
2.0kW |
3.0kW |
5.0kW |
|||
Input power supply |
Voltage/frequency |
Main circuit |
3-phase 200 to 230 VAC, 50/60 Hz, 270 to 320 VDC |
|||||
Control circuit |
Single-phase 200 to 230 VAC, 50/60 Hz |
|||||||
Main circuit/control circuit |
Allowable voltage fluctuation |
170 to 253 VAC |
||||||
Allowable frequency fluctuation |
±5% or less |
|||||||
Allowable instantaneous outage time |
Main circuit |
Full-stop (100% down): 0.5 cycles, half-stop (50% down): 1 cycle |
||||||
Control circuit |
Approx 100ms |
|||||||
Overvoltage category |
III |
|||||||
Control method |
3-phase full-wave rectification, IGBT, PWM control, sine wave current drive method |
|||||||
Feedback |
20-bit serial encoder (incremental, absolute) communication |
|||||||
Operating environment |
Operating ambient temperature |
0 to +55°C (no freezing) |
||||||
Ambient storage temperature |
-20 to +70°C (no freezing) |
|||||||
Ambient operating/storage humidity |
90%RH or less (no condensation) |
|||||||
Vibration resistance |
4.9 m/s2 (conforms to JIS C 60068-2-6) |
|||||||
Shock resistance |
19.6 m/s2 (conforms to JIS C 60068-2-27) |
|||||||
Operating atmosphere (enclosure rating/pollution degree) |
Pollution degree: 2 (within a control panel that has a rating of IP54 or higher), however, · No corrosive or flammable gas present · A location that is not subject to water, oil, or drugs · No dust present |
|||||||
Altitude |
1,000 m or less above sea level |
|||||||
Approved standards |
UL/CSA standards |
UL508C, CSA C22.2 number 14 |
||||||
CE marking |
Low-voltage directive |
EN50178 |
||||||
EMI |
EN55011 Class A, EN61800-3 |
|||||||
EMS |
EN61800-3, EN61000-6-2 |
|||||||
North American EMI standards |
FCC Part 15 B, ICES-003, Class A |
|||||||
Structure |
Type |
Base mounting attachment |
||||||
Protection |
Open, forced |
|||||||
Lowest insulation resistance value |
1 MΩ or more, tested with a 500 VDC megger |
|||||||
Insulation withstand voltage |
1,500 VAC or more (between the primary side and the earth terminal), 1,800 VAC or more (between the primary side and the secondary side) |
|||||||
Weight |
Approx 1.5kg |
Approx 2.4kg |
Approx 2.9kg |
Approx 4.7kg |
||||
Performance specifications |
Performance |
Speed control range |
1 to 5,000 (under the condition that the load torque is less than or equal to the rated torque) |
|||||
Speed fluctuation rate |
During load fluctuation |
±0.01% or less with a load fluctuation between 0 and 100% (at the rated rotation speed) |
||||||
When the voltage of the main circuit fluctuates |
0% at the rated voltage ±10% (at the rated rotation speed) |
|||||||
When the ambient temperature fluctuates |
±0.1% or less when the ambient temperature is between 0 and +50°C (at the rated rotation speed) |
|||||||
Torque control accuracy (reproducibility) |
±1% |
|||||||
Speed frequency response |
1.6 kHz (when JL = JM) * JL: load moment of inertia (motor axis conversion), JM: motor moment of inertia |
|||||||
Dynamic brake |
Built-in |
|||||||
Analogue monitor output for observation |
Monitor output such as motor rotation speed and torque instruction for observations, number of built-in channels: 2 |
|||||||
Regenerative resistor |
Built-in regenerative resistor |
Present (40 W) |
Present (50 W) |
Present (80 W) |
Present (180 W) |
|||
External regenerative resistor |
OP-84399 (220 W*2) |
OP-87073 (220 W*2) |
None*5 |
|||||
Display function |
Access window |
Status monitor, parameter settings, calibration, etc. |
||||||
CHARGE display LED |
CHARGE LED (orange) for checking the main circuit power supply input |
|||||||
Status |
Servo on, instruction input in progress, warning, MECHATROLINK-II communication in progress |
|||||||
Communication function |
USB communication |
Function |
Status display, parameter settings, calibration, etc. |
|||||
Connection device |
PC |
|||||||
Protection function |
Overcurrent, overvoltage, insufficient voltage, overload, regeneration error, etc. |
|||||||
Other functions |
Auto calibration, absolute position system, etc. |
|||||||
I/O specifications |
MECHATROLINK-II type |
Control I/O |
Input signal: Number of channels |
8CH |
||||
Input signal: Function |
Forced stop (FSTOP), forward rotation side limit switch (LSP), reverse rotation side limit switch (LSN), external latch signals 1 to 3 (EXT1, EXT2, EXT3), forward rotation side torque limit selection (PTL), reverse rotation side torque limit selection (NT |
|||||||
Output signal: Number of channels |
4CH |
|||||||
Output signal: Function |
Alarm (ALARM), operation preparation complete (RDY), in position (INPOS), speed matching (VCMP), electromagnetic brake timing (BRAKE), torque control in progress (TLM), speed control in progress (VLM), warning (WARN), zero-speed detection (ZSP), near posi |
|||||||
Encoder division pulse output |
A-phase (A+, A-), B-phase (B+, B-), Z-phase (Z+, Z-): line-driver output;*3 Z-phase (ZOC): open-collector output; number of division pulses: 1.6 Mpps maximum (6.4 MHz when 2-phase 4× selected)*4 |
|||||||
Pulse/Analogue input type |
Control I/O |
Input signal: Number of channels |
― |
|||||
Input signal: Function |
||||||||
Output signal: Number of channels |
||||||||
Output signal: Function |
||||||||
Encoder division pulse output |
||||||||
Position control |
Pulse string input: Command pulse format |
|||||||
Pulse string input: Input format |
||||||||
Pulse string input: Input frequency |
||||||||
Speed control |
Analogue input: Command voltage |
|||||||
Analogue input: Input impedance |
||||||||
Analogue input: Circuit time constant |
||||||||
Speed selection |
||||||||
Torque control |
Analogue input: Command voltage |
|||||||
Analogue input: Input impedance |
||||||||
Analogue input: Circuit time constant |
||||||||
Communication specifications (MECHATROLINK-II type only) |
MECHATROLINK communication |
Station address |
41H to 5FH (Up to 30 slave stations can be connected. The 10s digit is selected from the access window, and the 1s digit is selected with the rotary switch.) |
|||||
Transmission speed |
MECHATROLINK-II |
10 Mbps (selected from the access window) |
||||||
MECHATROLINK-I |
4 Mbps (selected from the access window) |
|||||||
Transmission frequency |
MECHATROLINK-II |
250 µs, 0.5 ms to 4.0 ms (multiples of 0.5) |
||||||
MECHATROLINK-I |
2ms |
|||||||
Transmission byte number |
MECHATROLINK-II |
17 bytes/station, 32 bytes/station (selected from the access window) |
||||||
MECHATROLINK-I |
17 bytes/station |
|||||||
Command method |
Operation specifications |
Position control, speed control, and torque control performed by way of MECHATROLINK communication |
||||||
Command input |
MECHATROLINK-II communication commands (such as sequence, motion, data setting and reference, monitor, and adjustment) |
|||||||
I/O terminal specifications and wiring |
General-purpose input (DI-1) |
Maximum input voltage |
26.4 VDC |
|||||
Input rated voltage |
24 VDC (5mA) |
|||||||
Minimum ON voltage |
19 VDC |
|||||||
Maximum OFF current |
0.1mA |
|||||||
Common ground |
Common (MECHATROLINK-II type servo amplifiers only have positive commons.) |
|||||||
General-purpose output (DO-1) |
Output |
Open-collector output |
||||||
Rated load |
30 VDC (30mA) |
|||||||
Leakage current (at OFF) |
0.1mA |
|||||||
Residual voltage (at ON) |
1.6 VDC or less |
|||||||
Common ground |
Common |
|||||||
2-wire method compatible input (DI-2) |
Maximum input voltage |
26.4 VDC |
||||||
Input rated voltage |
24 VDC (9mA) |
|||||||
Minimum ON voltage |
19 VDC |
|||||||
Maximum OFF current |
1.5mA |
|||||||
Common ground |
Common (MECHATROLINK-II type servo amplifiers only have positive commons.) |
|||||||
2-wire method compatible high-speed input (DI-3) |
Maximum input voltage |
26.4 VDC |
||||||
Input rated voltage |
24 VDC (11mA) |
|||||||
Minimum ON voltage |
19 VDC |
|||||||
Maximum OFF current |
1.5mA |
|||||||
Common ground |
Common |
|||||||
Z phase open-collector output (DO-2) |
Output |
Non-isolated open-collector output |
||||||
Rated load |
30 VDC (30mA) |
|||||||
Leakage current (at OFF) |
0.1mA |
|||||||
Residual voltage (at ON) |
1.2 VDC or less |
|||||||
Common ground |
Non-isolated |
|||||||
Output frequency |
50kHz |
|||||||
Encoder output (DO-E) |
Output |
Differential line-driver output |
||||||
Output voltage |
Corresponds to AM26C31 |
|||||||
Common ground |
Independent (non-isolated) |
|||||||
Output frequency |
Phase difference: 1.6 Mpps (after 4×: 6.4 MHz) |
|||||||
*1 When used with the amount of current listed above, the duration of the rush current is 20 ms or lower. |
Model |
SV-005L1 |
SV-010L1 |
SV-020L1 |
SV-040L1 |
|||
Image |
|
|
|
|
|||
Power supply/current capacity and power loss |
Maximum applicable motor capacity Single-phase 100 VAC |
50 W |
100 W |
200 W |
400 W |
||
Power capacity (VA) per amplifier Single-phase 100 VAC |
200 VA |
300 VA |
700 VA |
1400 VA |
|||
Output current Continuous |
Single-phase 100 VAC |
0.66 Arms |
0.91 Arms |
2.1 Arms |
2.8 Arms |
||
Output current Maximum |
Single-phase 100 VAC |
2.1 Arms |
2.9 Arms |
6.5 Arms |
9.3 Arms |
||
Main circuit power loss Single-phase 100 VAC |
5.4 W |
7.8 W |
14.4 W |
25.6 W |
|||
Control circuit power loss Single-phase 100 VAC |
17 W |
||||||
Total power loss Single-phase 100 VAC |
22.4 W |
24.8 W |
31.4 W |
42.6 W |
|||
Input rated current |
Main circuit Single-phase 100 VAC |
1.5 Arms |
2.5 Arms |
5 Arms |
10 Arms |
||
Control circuit Single-phase 100 VAC |
0.38 Arms |
||||||
Rush current |
Main circuit Single-phase 100 VAC |
16.5 A*1 |
|||||
Control circuit Single-phase 100 VAC |
35 A*1 |
||||||
General specifications |
Type |
For 100 V |
|||||
Capacity |
50W |
100W |
200W |
400W |
|||
Input power supply |
Voltage/frequency |
Main circuit |
Single phase 100 to 115 VAC, 50/60 Hz |
||||
Control circuit |
|||||||
Main circuit/control circuit |
Allowable voltage fluctuation |
85 to 127 VAC |
|||||
Allowable frequency fluctuation |
±5% or less |
||||||
Allowable instantaneous outage time |
Main circuit |
Full (100% down): 0.5 cycle, Partial (50% down): 1 cycle |
|||||
Control circuit |
Approx 65ms |
||||||
Overvoltage category |
III |
||||||
Control method |
3-phase full-wave rectification, IGBT PWM control, sinusoidal current drive system |
||||||
Feedback |
|||||||
Operating environment |
Operating ambient temperature |
0 to +55°C (no freezing) |
|||||
Ambient storage temperature |
-20 to +70°C (no freezing) |
||||||
Ambient operating/storage humidity |
90%RH or less (no condensation) |
||||||
Vibration resistance |
4.9 m/s2 (conforms to JIS C 60068-2-6) |
||||||
Shock resistance |
19.6 m/s2 (conforms to JIS C 60068-2-27) |
||||||
Operating atmosphere (enclosure rating/pollution degree) |
Pollution degree: 2 (within a control panel that has a rating of IP54 or higher), however, · No corrosive or flammable gas present · A location that is not subject to water, oil, or drugs · No dust present |
||||||
Altitude |
1,000 m or less above sea level |
||||||
Approved standards |
UL/CSA standards |
UL508C, and CSA C22.2 No.14 |
|||||
CE marking |
Low-voltage directive |
EN50178 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3, EN61000-6-2 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Structure |
Type |
Base mounting attachment |
|||||
Protection |
Open, forced |
||||||
Lowest insulation resistance value |
1 MΩ or more, tested with a 500 VDC megger |
||||||
Insulation withstand voltage |
1,500 VAC or more (between the primary side and the earth terminal), 1,800 VAC or more (between the primary side and the secondary side) |
||||||
Weight |
Approx 1.1kg |
Approx 1.5kg |
|||||
Performance specifications |
Performance |
Speed control range |
1 to 5,000 (under the condition that the load torque is less than or equal to the rated torque) |
||||
Speed fluctuation rate |
During load fluctuation |
±0.01% or less with a load fluctuation between 0 and 100% (at the rated rotation speed) |
|||||
When the voltage of the main circuit fluctuates |
0% at the rated voltage ±10% (at the rated rotation speed) |
||||||
When the ambient temperature fluctuates |
±0.1% or less when the ambient temperature is between 0 and +50°C (at the rated rotation speed) |
||||||
Torque control accuracy (reproducibility) |
±1% |
||||||
Speed frequency response |
1.6 kHz (when JL = JM) * JL: load moment of inertia (motor axis conversion), JM: motor moment of inertia |
||||||
Dynamic brake |
Built-in |
||||||
Analogue monitor output for observation |
Monitor output such as motor rotation speed and torque instruction for observations, number of built-in channels: 2 |
||||||
Regenerative resistor |
Built-in regenerative resistor |
None |
|||||
External regenerative resistor |
OP-84399 (220 W*2) |
||||||
Display function |
Access window |
Status monitor, parameter settings, calibration, etc. |
|||||
CHARGE display LED |
CHARGE LED (orange) for checking the main circuit power supply input |
||||||
Status |
Servo on, instruction input in progress, warning, MECHATROLINK-II communication in progress |
||||||
Communication function |
USB communication |
Function |
Status display, parameter settings, calibration, etc. |
||||
Connection device |
PC |
||||||
Protection function |
Overcurrent, overvoltage, insufficient voltage, overload, regeneration error, etc. |
||||||
Other functions |
Auto calibration, absolute position system, etc. |
||||||
I/O specifications |
MECHATROLINK-II type |
Control I/O |
Input signal: Number of channels |
8CH |
|||
Input signal: Function |
Forced stop (FSTOP), forward rotation side limit switch (LSP), reverse rotation side limit switch (LSN), external latch signals 1 to 3 (EXT1, EXT2, EXT3), forward rotation side torque limit selection (PTL), reverse rotation side torque limit selection (NT |
||||||
Output signal: Number of channels |
4CH |
||||||
Output signal: Function |
Alarm (ALARM), operation preparation complete (RDY), in position (INPOS), speed matching (VCMP), electromagnetic brake timing (BRAKE), torque control in progress (TLM), speed control in progress (VLM), warning (WARN), zero-speed detection (ZSP), near posi |
||||||
Encoder division pulse output |
A-phase (A+, A-), B-phase (B+, B-), Z-phase (Z+, Z-): line-driver output;*3 Z-phase (ZOC): open-collector output; number of division pulses: 1.6 Mpps maximum (6.4 MHz when 2-phase 4× selected)*4 |
||||||
Communication specifications (MECHATROLINK-II type only) |
MECHATROLINK communication |
Station address |
41 H to 5 FH (up to 30 slave stations connected) |
||||
Transmission speed |
MECHATROLINK-II |
10 Mbps (selected with access window) |
|||||
MECHATROLINK-I |
4 Mbps (selected with access window) |
||||||
Transmission frequency |
MECHATROLINK-II |
250 µs, 0.5 to 4.0 ms (multiples of 0.5) |
|||||
MECHATROLINK-I |
2ms |
||||||
Transmission byte number |
MECHATROLINK-II |
17 bytes/station, 32 bytes/station (selected with access window) |
|||||
MECHATROLINK-I |
17 bytes/station |
||||||
Command method |
Operation specifications |
Position control, speed control, and torque control performed by way of MECHATROLINK communication |
|||||
Command input |
MECHATROLINK-II Command (sequence control Programme/motion/data setting/reference/monitoring/adjustment etc) |
||||||
I/O terminal specifications and wiring |
General-purpose input (DI-1) |
Maximum input voltage |
26.4 VDC |
||||
Input rated voltage |
24 VDC (5mA) |
||||||
Minimum ON voltage |
19 VDC |
||||||
Maximum OFF current |
0.1mA |
||||||
Common ground |
Common (MECHATROLINK-II type servo amplifiers only have positive commons.) |
||||||
General-purpose output (DO-1) |
Output |
Open-collector output |
|||||
Rated load |
30 VDC (30mA) |
||||||
Leakage current (at OFF) |
0.1mA |
||||||
Residual voltage (at ON) |
1.6 VDC or less |
||||||
Common ground |
Common |
||||||
2-wire method compatible input (DI-2) |
Maximum input voltage |
26.4 VDC |
|||||
Input rated voltage |
24 VDC (9mA) |
||||||
Minimum ON voltage |
19 VDC |
||||||
Maximum OFF current |
1.5mA |
||||||
Common ground |
Common (MECHATROLINK-II type servo amplifiers only have positive commons.) |
||||||
2-wire method compatible high-speed input (DI-3) |
Maximum input voltage |
26.4 VDC |
|||||
Input rated voltage |
24 VDC (11mA) |
||||||
Minimum ON voltage |
19 VDC |
||||||
Maximum OFF current |
1.5mA |
||||||
Common ground |
Common |
||||||
Z phase open-collector output (DO-2) |
Output |
Non-isolated open-collector output |
|||||
Rated load |
30 VDC (30mA) |
||||||
Leakage current (at OFF) |
0.1mA |
||||||
Residual voltage (at ON) |
1.2 VDC or less |
||||||
Common ground |
Non-isolated |
||||||
Output frequency |
50kHz |
||||||
Encoder output (DO-E) |
Output |
Differential line-driver output |
|||||
Output voltage |
Corresponds to AM26C31 |
||||||
Common ground |
Independent (non-isolated) |
||||||
Output frequency |
Phase difference: 1.6 Mpps (after 4×: 6.4 MHz) |
||||||
*1 When used with the amount of current listed above, the duration of the rush current is 20 ms or lower. |
Model |
SV-B005AK |
SV-B005AS |
SV-B005CK |
SV-B005CS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Motor with electromagnetic brake, Absolute Type (ABS) |
Motor with electromagnetic brake, Incremental Type (INC) |
||||
Applicable servo amplifiers |
SV-005** |
||||||
Rated output |
50 W |
||||||
Rated torque |
0.159 N m |
||||||
Instantaneous maximum torque |
0.557 N m |
||||||
Rated current |
0.61 Arms |
||||||
Instantaneous maximum current |
2.1 Arms |
||||||
Rated rotation speed |
3000 min-1 |
||||||
Highest rotation speed |
6000 min-1 |
||||||
Torque constant |
0.285 N m/Arms |
||||||
Rotor moment of inertia |
0.0561 ×10-4kg・m2 |
||||||
Rated power rate |
6.11 kW/s |
||||||
Rated angle acceleration |
38400 rad/s2 |
||||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
20 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP65 (excluding connectors and shaft opening) |
||||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class B |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 0.6kg |
||||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions: |
||||||
Electromagnetic brake specifications |
Capacity |
5.5 W |
Model |
SV-B010AK |
SV-B010AS |
SV-B010CK |
SV-B010CS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Motor with electromagnetic brake, Absolute Type (ABS) |
Motor with electromagnetic brake, Incremental Type (INC) |
||||
Applicable servo amplifiers |
SV-010** |
||||||
Rated output |
100 W |
||||||
Rated torque |
0.318 N m |
||||||
Instantaneous maximum torque |
1.11 N m |
||||||
Rated current |
0.84 Arms |
||||||
Instantaneous maximum current |
2.9 Arms |
||||||
Rated rotation speed |
3000 min-1 |
||||||
Highest rotation speed |
6000 min-1 |
||||||
Torque constant |
0.413 N m/Arms |
||||||
Rotor moment of inertia |
0.0812 ×10-4kg・m2 |
||||||
Rated power rate |
15.2 kW/s |
||||||
Rated angle acceleration |
47800 rad/s2 |
||||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
20 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP65 (excluding connectors and shaft opening) |
||||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class B |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 0.7kg |
||||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions: |
||||||
Electromagnetic brake specifications |
Capacity |
5.5 W |
Model |
SV-B020AK |
SV-B020AS |
SV-B020CK |
SV-B020CS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Motor with electromagnetic brake, Absolute Type (ABS) |
Motor with electromagnetic brake, Incremental Type (INC) |
||||
Applicable servo amplifiers |
SV-020** |
||||||
Rated output |
200 W |
||||||
Rated torque |
0.637 N m |
||||||
Instantaneous maximum torque |
2.23 N m |
||||||
Rated current |
1.6 Arms |
||||||
Instantaneous maximum current |
5.8 Arms |
||||||
Rated rotation speed |
3000 min-1 |
||||||
Highest rotation speed |
6000 min-1 |
||||||
Torque constant |
0.435 N m/Arms |
||||||
Rotor moment of inertia |
0.323 ×10-4kg・m2 |
||||||
Rated power rate |
15.7 kW/s |
||||||
Rated angle acceleration |
24600 rad/s2 |
||||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
15 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP65 (excluding connectors and shaft opening) |
||||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class B |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 1.5kg |
||||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions: |
||||||
Electromagnetic brake specifications |
Capacity |
6 W |
Model |
SV-B040AK |
SV-B040AS |
SV-B040CK |
SV-B040CS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Motor with electromagnetic brake, Absolute Type (ABS) |
Motor with electromagnetic brake, Incremental Type (INC) |
||||
Applicable servo amplifiers |
SV-040** |
||||||
Rated output |
400 W |
||||||
Rated torque |
1.27 N m |
||||||
Instantaneous maximum torque |
4.46 N m |
||||||
Rated current |
2.7 Arms |
||||||
Instantaneous maximum current |
9.3 Arms |
||||||
Rated rotation speed |
3000 min-1 |
||||||
Highest rotation speed |
6000 min-1 |
||||||
Torque constant |
0.512 N m/Arms |
||||||
Rotor moment of inertia |
0.506 ×10-4kg・m2 |
||||||
Rated power rate |
36.5 kW/s |
||||||
Rated angle acceleration |
28800 rad/s2 |
||||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
10 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP65 (excluding connectors and shaft opening) |
||||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class B |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 1.9kg |
||||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions: |
||||||
Electromagnetic brake specifications |
Capacity |
6 W |
Model |
SV-B075AK |
SV-B075AS |
SV-B075CK |
SV-B075CS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Motor with electromagnetic brake, Absolute Type (ABS) |
Motor with electromagnetic brake, Incremental Type (INC) |
||||
Applicable servo amplifiers |
SV-075** |
||||||
Rated output |
750 W |
||||||
Rated torque |
2.39 N m |
||||||
Instantaneous maximum torque |
8.36 N m |
||||||
Rated current |
4.7 Arms |
||||||
Instantaneous maximum current |
16.9 Arms |
||||||
Rated rotation speed |
3000 min-1 |
||||||
Highest rotation speed |
6000 min-1 |
||||||
Torque constant |
0.544 N m/Arms |
||||||
Rotor moment of inertia |
1.74 ×10-4kg・m2 |
||||||
Rated power rate |
36.3 kW/s |
||||||
Rated angle acceleration |
15200 rad/s2 |
||||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
10 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP65 (excluding connectors and shaft opening) |
||||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class B |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 3.6kg |
||||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions: |
||||||
Electromagnetic brake specifications |
Capacity |
6.5 W |
Model |
SV-B100AK |
SV-B100AS |
SV-B150AK |
SV-B150AS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Motor with electromagnetic brake, Absolute Type (ABS) |
|||||
Applicable servo amplifiers |
SV-100** |
SV-150*2 |
|||||
Rated output |
0.85 kW |
1.3 kW |
|||||
Rated torque |
5.39 N m |
8.34 N m |
|||||
Instantaneous maximum torque |
13.8 N m |
23.3 N m |
|||||
Rated current |
6.9 Arms |
10.7 Arms |
|||||
Instantaneous maximum current |
17 Arms |
28 Arms |
|||||
Rated rotation speed |
1500 min-1 |
||||||
Highest rotation speed |
3000 min-1 |
||||||
Torque constant |
0.859 N m/Arms |
0.891 N m/Arms |
|||||
Rotor moment of inertia |
16 ×10-4kg・m2 |
22 ×10-4kg・m2 |
|||||
Rated power rate |
18.2 kW/s |
31.6 kW/s |
|||||
Rated angle acceleration |
3370 rad/s2 |
3790 rad/s2 |
|||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
5 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
49 m/s2 with the servo motor flange used as reference surface |
|||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP65 (excluding connectors and shaft opening) |
Totally enclosed, self-cooling, IP67 (excluding connectors and shaft opening) |
|||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class F |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 7.5kg |
Approx 9.0kg |
|||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions: |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached aluminium heatsink:50 W to 100 W: 200 × 200 × 6 [mm]200 W to 750 W: 250 × 250 × 6 [mm]Rates torque of 1 kW to 5 kW is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached iron heatsink:1 kW to 2 kW: 400 × 400 × 20 [mm]3 kW, 5 kW: 550 × 550 × 30 [mm] |
|||||
Electromagnetic brake specifications |
Capacity |
10 W |
Model |
SV-B200AK |
SV-B200AS |
SV-B300AK |
SV-B300AS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Motor with electromagnetic brake, Absolute Type (ABS) |
|||||
Applicable servo amplifiers |
SV-150*2 |
||||||
Rated output |
1.8 kW |
2.9 kW*1 |
|||||
Rated torque |
11.5 N m |
18.6 N m*1 |
|||||
Instantaneous maximum torque |
28.7 N m |
45.1 N m |
|||||
Rated current |
16.7 Arms |
23.8 Arms*1 |
|||||
Instantaneous maximum current |
42 Arms |
56 Arms |
|||||
Rated rotation speed |
1500 min-1 |
||||||
Highest rotation speed |
3000 min-1 |
||||||
Torque constant |
0.748 N m/Arms |
0.848 N m/Arms |
|||||
Rotor moment of inertia |
28.1 ×10-4kg・m2 |
54.5 ×10-4kg・m2 |
|||||
Rated power rate |
47.1 kW/s |
63.5 kW/s |
|||||
Rated angle acceleration |
4090 rad/s2 |
3410 rad/s2 |
|||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
5 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP67 (excluding connectors and shaft opening) |
||||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class F |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 11.0kg |
Approx 19.5kg |
|||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached aluminium heatsink:50 W to 100 W: 200 × 200 × 6 [mm]200 W to 750 W: 250 × 250 × 6 [mm]Rates torque of 1 kW to 5 kW is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached iron heatsink:1 kW to 2 kW: 400 × 400 × 20 [mm]3 kW, 5 kW: 550 × 550 × 30 [mm] |
||||||
Electromagnetic brake specifications |
Capacity |
10 W |
18.5 W |
||||
*1 If the SV-M300A* and SV-B300A* are used in combination with the SV-300*2, the following ratings will be different. Rated output: 2.4 kW. Rated torque: 15.1 N m. Ratio of allowable load to moment of inertia: 3 times. Rated current: 19.6 Arms. |
Model |
SV-B500AK |
SV-B500AS |
|||
Image |
|
|
|||
General specifications |
Type |
Motor with electromagnetic brake, Absolute Type (ABS) |
|||
Applicable servo amplifiers |
SV-150*2 |
||||
Rated output |
4.4 kW |
||||
Rated torque |
28.4 N m |
||||
Instantaneous maximum torque |
71.1 N m |
||||
Rated current |
32.8 Arms |
||||
Instantaneous maximum current |
84 Arms |
||||
Rated rotation speed |
1500 min-1 |
||||
Highest rotation speed |
3000 min-1 |
||||
Torque constant |
0.934 N m/Arms |
||||
Rotor moment of inertia |
76 ×10-4kg・m2 |
||||
Rated power rate |
106 kW/s |
||||
Rated angle acceleration |
3740 rad/s2 |
||||
Excitation method |
Permanent magnet |
||||
Allowable load moment of inertia ratio |
5 times |
||||
Resolution |
20bit |
||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||
Enclosure rating |
Totally enclosed, self-cooling, IP67 (excluding connectors and shaft opening) |
||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||
Altitude |
1,000 m max. above sea level |
||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||
EMI |
EN55011 Class A, EN61800-3 |
||||
EMS |
EN61800-3 |
||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||
Insulation class |
Class F |
||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||
Weight |
Approx 23.5kg |
||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached aluminium heatsink:50 W to 100 W: 200 × 200 × 6 [mm]200 W to 750 W: 250 × 250 × 6 [mm]Rates torque of 1 kW to 5 kW is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached iron heatsink:1 kW to 2 kW: 400 × 400 × 20 [mm]3 kW, 5 kW: 550 × 550 × 30 [mm] |
||||
Electromagnetic brake specifications |
Capacity |
18.5 W |
Model |
SV-M005AK |
SV-M005AS |
SV-M005CK |
SV-M005CS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Standard motor, Absolute Type (ABS) |
Standard motor, Incremental Type (INC) |
||||
Applicable servo amplifiers |
SV-005** |
||||||
Rated output |
50 W |
||||||
Rated torque |
0.159 N m |
||||||
Instantaneous maximum torque |
0.557 N m |
||||||
Rated current |
0.61 Arms |
||||||
Instantaneous maximum current |
2.1 Arms |
||||||
Rated rotation speed |
3000 min-1 |
||||||
Highest rotation speed |
6000 min-1 |
||||||
Torque constant |
0.285 N m/Arms |
||||||
Rotor moment of inertia |
0.0414 ×10-4kg・m2 |
||||||
Rated power rate |
6.11 kW/s |
||||||
Rated angle acceleration |
38400 rad/s2 |
||||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
20 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP65 (excluding connectors and shaft opening) |
||||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class B |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 0.3kg |
||||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions: |
Model |
SV-M010AK |
SV-M010AS |
SV-M010CK |
SV-M010CS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Standard motor, Absolute Type (ABS) |
Standard motor, Incremental Type (INC) |
||||
Applicable servo amplifiers |
SV-010** |
||||||
Rated output |
100 W |
||||||
Rated torque |
0.318 N m |
||||||
Instantaneous maximum torque |
1.11 N m |
||||||
Rated current |
0.84 Arms |
||||||
Instantaneous maximum current |
2.9 Arms |
||||||
Rated rotation speed |
3000 min-1 |
||||||
Highest rotation speed |
6000 min-1 |
||||||
Torque constant |
0.413 N m/Arms |
||||||
Rotor moment of inertia |
0.0665 ×10-4kg・m2 |
||||||
Rated power rate |
15.2 kW/s |
||||||
Rated angle acceleration |
47800 rad/s2 |
||||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
20 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP65 (excluding connectors and shaft opening) |
||||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class B |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 0.4kg |
||||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions: |
Model |
SV-M020AK |
SV-M020AS |
SV-M020CK |
SV-M020CS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Standard motor, Absolute Type (ABS) |
Standard motor, Incremental Type (INC) |
||||
Applicable servo amplifiers |
SV-020** |
||||||
Rated output |
200 W |
||||||
Rated torque |
0.637 N m |
||||||
Instantaneous maximum torque |
2.23 N m |
||||||
Rated current |
1.6 Arms |
||||||
Instantaneous maximum current |
5.8 Arms |
||||||
Rated rotation speed |
3000 min-1 |
||||||
Highest rotation speed |
6000 min-1 |
||||||
Torque constant |
0.435 N m/Arms |
||||||
Rotor moment of inertia |
0.259 ×10-4kg・m2 |
||||||
Rated power rate |
15.7 kW/s |
||||||
Rated angle acceleration |
24600 rad/s2 |
||||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
15 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP65 (excluding connectors and shaft opening) |
||||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class B |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 0.9kg |
||||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions: |
Model |
SV-M040AK |
SV-M040AS |
SV-M040CK |
SV-M040CS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Standard motor, Absolute Type (ABS) |
Standard motor, Incremental Type (INC) |
||||
Applicable servo amplifiers |
SV-040** |
||||||
Rated output |
400 W |
||||||
Rated torque |
1.27 N m |
||||||
Instantaneous maximum torque |
4.46 N m |
||||||
Rated current |
2.7 Arms |
||||||
Instantaneous maximum current |
9.3 Arms |
||||||
Rated rotation speed |
3000 min-1 |
||||||
Highest rotation speed |
6000 min-1 |
||||||
Torque constant |
0.512 N m/Arms |
||||||
Rotor moment of inertia |
0.442 ×10-4kg・m2 |
||||||
Rated power rate |
36.5 kW/s |
||||||
Rated angle acceleration |
28800 rad/s2 |
||||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
10 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP65 (excluding connectors and shaft opening) |
||||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class B |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 1.3kg |
||||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions: |
Model |
SV-M075AK |
SV-M075AS |
SV-M075CK |
SV-M075CS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Standard motor, Absolute Type (ABS) |
Standard motor, Incremental Type (INC) |
||||
Applicable servo amplifiers |
SV-075** |
||||||
Rated output |
750 W |
||||||
Rated torque |
2.39 N m |
||||||
Instantaneous maximum torque |
8.36 N m |
||||||
Rated current |
4.7 Arms |
||||||
Instantaneous maximum current |
16.9 Arms |
||||||
Rated rotation speed |
3000 min-1 |
||||||
Highest rotation speed |
6000 min-1 |
||||||
Torque constant |
0.544 N m/Arms |
||||||
Rotor moment of inertia |
1.57 ×10-4kg・m2 |
||||||
Rated power rate |
36.3 kW/s |
||||||
Rated angle acceleration |
15200 rad/s2 |
||||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
10 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP65 (excluding connectors and shaft opening) |
||||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class B |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 2.7kg |
||||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions: |
Model |
SV-M100AK |
SV-M100AS |
SV-M150AK |
SV-M150AS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Standard motor, Absolute Type (ABS) |
|||||
Applicable servo amplifiers |
SV-100** |
SV-150*2 |
|||||
Rated output |
0.85 kW |
1.3 kW |
|||||
Rated torque |
5.39 N m |
8.34 N m |
|||||
Instantaneous maximum torque |
13.8 N m |
23.3 N m |
|||||
Rated current |
6.9 Arms |
10.7 Arms |
|||||
Instantaneous maximum current |
17 Arms |
28 Arms |
|||||
Rated rotation speed |
1500 min-1 |
||||||
Highest rotation speed |
3000 min-1 |
||||||
Torque constant |
0.859 N m/Arms |
0.891 N m/Arms |
|||||
Rotor moment of inertia |
13.9 ×10-4kg・m2 |
19.9 ×10-4kg・m2 |
|||||
Rated power rate |
20.9 kW/s |
35 kW/s |
|||||
Rated angle acceleration |
3880 rad/s2 |
4190 rad/s2 |
|||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
5 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
49 m/s2 with the servo motor flange used as reference surface |
|||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP65 (excluding connectors and shaft opening) |
Totally enclosed, self-cooling, IP67 (excluding connectors and shaft opening) |
|||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class F |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 5.5kg |
Approx 7.1kg |
|||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions: |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached aluminium heatsink:50 W to 100 W: 200 × 200 × 6 [mm]200 W to 750 W: 250 × 250 × 6 [mm]Rates torque of 1 kW to 5 kW is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached iron heatsink:1 kW to 2 kW: 400 × 400 × 20 [mm]3 kW, 5 kW: 550 × 550 × 30 [mm] |
|||||
Electromagnetic brake specifications |
Capacity |
10 W |
Model |
SV-M200AK |
SV-M200AS |
SV-M300AK |
SV-M300AS |
|||
Image |
|
|
|
|
|||
General specifications |
Type |
Standard motor, Absolute Type (ABS) |
|||||
Applicable servo amplifiers |
SV-200*2 |
SV-300*2 |
|||||
Rated output |
1.8 kW |
2.9 kW*1 |
|||||
Rated torque |
11.5 N m |
18.6 N m*1 |
|||||
Instantaneous maximum torque |
28.7 N m |
45.1 N m |
|||||
Rated current |
16.7 Arms |
23.8 Arms*1 |
|||||
Instantaneous maximum current |
42 Arms |
56 Arms |
|||||
Rated rotation speed |
1500 min-1 |
||||||
Highest rotation speed |
3000 min-1 |
||||||
Torque constant |
0.748 N m/Arms |
0.848 N m/Arms |
|||||
Rotor moment of inertia |
26 ×10-4kg・m2 |
46 ×10-4kg・m2 |
|||||
Rated power rate |
50.9 kW/s |
75.2 kW/s |
|||||
Rated angle acceleration |
4420 rad/s2 |
4040 rad/s2 |
|||||
Excitation method |
Permanent magnet |
||||||
Allowable load moment of inertia ratio |
5 times |
||||||
Resolution |
20bit |
||||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||||
Enclosure rating |
Totally enclosed, self-cooling, IP67 (excluding connectors and shaft opening) |
||||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||||
Altitude |
1,000 m max. above sea level |
||||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||||
EMI |
EN55011 Class A, EN61800-3 |
||||||
EMS |
EN61800-3 |
||||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||||
Insulation class |
Class F |
||||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||||
Weight |
Approx 8.6kg |
Approx 13.5kg |
|||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached aluminium heatsink:50 W to 100 W: 200 × 200 × 6 [mm]200 W to 750 W: 250 × 250 × 6 [mm]Rates torque of 1 kW to 5 kW is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached iron heatsink:1 kW to 2 kW: 400 × 400 × 20 [mm]3 kW, 5 kW: 550 × 550 × 30 [mm] |
||||||
*1 If the SV-M300A* and SV-B300A* are used in combination with the SV-300*2, the following ratings will be different. Rated output: 2.4 kW. Rated torque: 15.1 N m. Ratio of allowable load to moment of inertia: 3 times. Rated current: 19.6 Arms. |
Model |
SV-M500AK |
SV-M500AS |
|||
Image |
|
|
|||
General specifications |
Type |
Standard motor, Absolute Type (ABS) |
|||
Applicable servo amplifiers |
SV-500*2 |
||||
Rated output |
4.4 kW |
||||
Rated torque |
28.4 N m |
||||
Instantaneous maximum torque |
71.1 N m |
||||
Rated current |
32.8 Arms |
||||
Instantaneous maximum current |
84 Arms |
||||
Rated rotation speed |
1500 min-1 |
||||
Highest rotation speed |
3000 min-1 |
||||
Torque constant |
0.934 N m/Arms |
||||
Rotor moment of inertia |
67.5 ×10-4kg・m2 |
||||
Rated power rate |
119 kW/s |
||||
Rated angle acceleration |
4210 rad/s2 |
||||
Excitation method |
Permanent magnet |
||||
Allowable load moment of inertia ratio |
5 times |
||||
Resolution |
20bit |
||||
Operating environment |
Operating ambient temperature |
0 to +40°C (No freezing) |
|||
Ambient storage temperature |
-20 to +60°C (No freezing) |
||||
Ambient operating/storage humidity |
20 to 80%RH (no condensation) |
||||
Vibration resistance |
49 m/s2 with the servo motor flange used as reference surface |
||||
Shock resistance |
490 m/s2 for two times with the servo motor flange used as reference surface |
||||
Enclosure rating |
Totally enclosed, self-cooling, IP67 (excluding connectors and shaft opening) |
||||
Operating environment |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
||||
Altitude |
1,000 m max. above sea level |
||||
Approved standards |
UL/CSA standards |
UL1004 C22.2 No.100 |
|||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
|||
EMI |
EN55011 Class A, EN61800-3 |
||||
EMS |
EN61800-3 |
||||
North American EMI standards |
FCC Part15 B, ICES-003. Class A |
||||
Insulation class |
Class F |
||||
Insulation withstand voltage |
1500 VAC for 1 minute |
||||
Insulation resistance |
10 MΩ min. with 500 VDC megohmmeter |
||||
Weight |
Approx 17.5kg |
||||
Note |
Rates torque of 50 W to 750 W is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached aluminium heatsink:50 W to 100 W: 200 × 200 × 6 [mm]200 W to 750 W: 250 × 250 × 6 [mm]Rates torque of 1 kW to 5 kW is the continuous permissible torque values in the following conditions:-Ambient temperature: 40°C-Attached iron heatsink:1 kW to 2 kW: 400 × 400 × 20 [mm]3 kW, 5 kW: 550 × 550 × 30 [mm] |