Main Unit, Hand-protection Type, 24 Optical Axes GL-R24HG

GL-R24HG - Main Unit, Hand-protection Type, 24 Optical Axes

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

Software

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

GL-R24HG

Detection capability

ø25 mm

Total length

480mm

No. of beam

24

Detection height

505 mm

Protection height

460 mm

Beam axis spacing/Lens diameter

20 mm / ø5

Detecting distance

0.2 to 15 m

Effective aperture angle

Max. ±2.5° (When operating distance is 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronisation, One-line or
Optical synchronisation system (Channel 0)

ON→OFF

7

OFF→ON

49.3*1

All blocked→ON

64.9*2

Optical synchronisation system
(Channel A or B)

ON→OFF

9.5

OFF→ON

53*1

All blocked→ON

74.7*2

Detection mode

Turned on when light is being applied to all optical axes

Synchronisation between the transmitter and receiver

Optical synchronisation or Wire synchronisation (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*3

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

57

Receiver

72

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C (No freezing)

Storage temperature

-25 to +60 °C (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminium

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

660 g

Receiver

*1 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will
be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*2 “All blocked” means the situation where the GL-R operates in optical synchronisation system and the
transmitter and receiver is not synchronised (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronises the transmitter and receiver fi rst and then
determines the clear or blocked.
*3 When the GL-R is used under surrounding air temperatures between 50 to 55°C, the Maximum load current should not exceed 350 mA.

Data Sheet (PDF) Other Models